Cardiac potential and potential gradient fields generated by single, combined, and sequential shocks during ventricular defibrillation.

نویسندگان

  • J M Wharton
  • P D Wolf
  • W M Smith
  • P S Chen
  • D W Frazier
  • S Yabe
  • N Danieley
  • R E Ideker
چکیده

BACKGROUND Potential gradient field determination may be a helpful means of describing the effects of defibrillation shocks; however, potential gradient field requirements for defibrillation with different electrode configurations have not been established. METHODS AND RESULTS To evaluate the field requirements for defibrillation, potential fields during defibrillation shocks and the following ventricular activations were recorded with 74 epicardial electrodes in 12 open-chest dogs with the use of a computerized mapping system. Shock electrodes (2.64 cm2) were attached to the lateral right atrium (R), lateral left ventricular base (L), and left ventricular apex (V). Four electrode configurations were tested: single shocks of 14-msec duration given to two single anode-single cathode configurations, R:V and L:V, and to one dual anode-single cathode configuration, (R+L):V; and sequential 7-msec shocks separated by 1 msec given to R:V and L:V (R:V----L:V). Defibrillation threshold (DFT) current was significantly lower for R:V----L:V than for the other configurations and markedly higher for L:V. Despite these differences, the minimum potential gradients measured at DFT were not significantly different (approximately 6-7 V/cm for each electrode configuration). Potential gradient fields generated by the electrode configurations were markedly uneven, with a 15-27-fold change from lowest to highest gradient, with the greatest decrease in gradient occurring near the shock electrodes. Although gradient fields varied with the electrode configuration, all configurations produced weak fields along the right ventricular base. Early sites of epicardial activation after all unsuccessful shocks occurred in areas in which the field was weak; 87% occurred at sites with gradients less than 15 V/cm. Ventricular tachycardia originating in high gradient areas near shock electrodes followed 11 of 67 successful shocks. CONCLUSIONS These data suggest that 1) defibrillation fields created by small epicardial electrodes are very uneven; 2) achievement of a certain minimum potential gradient over both ventricles is necessary for ventricular defibrillation; 3) the difference in shock strengths required to achieve this minimum gradient over both ventricles may explain the differences in DFTs for various electrode configurations; and 4) high gradient areas in the uneven fields can induce ectopic activation after successful shocks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional potential gradient fields generated by intracardiac catheter and cutaneous patch electrodes.

BACKGROUND Defibrillation may be improved if electrode configurations can be found that create a larger and more even voltage gradient field across the heart. This study determined the magnitude of the shock gradient fields generated by four nonthoracotomy electrode configurations for defibrillation. METHODS AND RESULTS In six dogs, a catheter was inserted containing a right ventricular apica...

متن کامل

The potential gradient field created by epicardial defibrillation electrodes in dogs.

Knowledge of the potential gradient field created by defibrillation electrodes is important for the understanding and improvement of defibrillation. To obtain this knowledge by direct measurements, potentials were recorded from 60 epicardial, eight septal, and 36 right ventricular transmural electrodes in six open-chest dogs while 1 to 2 V shocks were given through defibrillation electrodes on ...

متن کامل

Epicardial mapping of ventricular defibrillation with monophasic and biphasic shocks in dogs.

To study the mechanism of defibrillation and the reason for the increased defibrillation efficacy of biphasic waveforms, the potential gradient in a 32 x 30-mm region of the right ventricle in 15 dogs was progressively lowered in four steps while a strong potential gradient field was maintained throughout the rest of the ventricular myocardium. The volume of right ventricle beneath the plaque w...

متن کامل

Conduction disturbances caused by high current density electric fields.

During internal defibrillation, potential gradients greater than 100 V/cm occur near defibrillation electrodes. Such strong fields may cause deleterious effects, including arrhythmias. This study determined 1) the effects of such strong fields on the propagation of activation and 2) whether these effects were different for monophasic and biphasic shocks. Voltages and potential gradients during ...

متن کامل

Mechanism of cardiac defibrillation in open-chest dogs with unipolar DC-coupled simultaneous activation and shock potential recordings.

The automatic implantable cardioverter-defibrillator has been shown to dramatically improve survival. The future refinement of these devices requires a clear understanding of their mechanism of action. We performed the following study to test two hypotheses: 1) When defibrillation is successful, fibrillating activity must be annihilated in a critical mass of both ventricles; and 2) when defibri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 85 4  شماره 

صفحات  -

تاریخ انتشار 1992