Comparative interference by haemolysis in automated assays for bilirubin at multiple analyte concentrations

نویسندگان

  • Robert A. Webster
  • Peter Molnar
  • Stephen E. Kahn
چکیده

The negative interference caused by haemolysis in manual bilirubin assays contrasts with the positive interference reported for some automated methods utilizing the same basic chemistry. A comparison was therefore made of the haemolysis interference associated with several automated bilirubin methodologies: multilayer film (Kodak Ektachem- total bilirubin (TBil), direct bilirubin (DBil), conjugated bilirubin (Bc), unconjugated bilirubin (Bu),; tableted reagents (Baxter Paramax- TBil, DBil); continuous flow (Technicon SMAC - TBil). Thirty serum pools were analysed (five concentrations of bilirubin, 2-229 mumol/l; six concentrations of haemoglobin, 0.00002-0.052 mmol/1). All methods, except one (Bc), exhibited both positive and negative interference, depending upon the relative haemoglobin and bilirubin concentrations. This interference, at any given haemoglobin concentration, was neither constant nor proportional with increasing bilirubin concentration. These complex patterns of interference suggest that the best characterization of interference is obtained when (1) both percentage-difference and absolute-difference 'interferographs' are plotted; and (2) the interference is determined at multiple analyte concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Ames' "Clini-Tek".

Reproducibility of reading "N-Multistix" dipsticks by a semi-automated urinalysis instrument (Ames' "Clini-Tek") has been described for artifically prepared samples. Glucose, ketone, urobilinogen, and nitrite showed high reproducibility (greater than 90%) for reading multiple samples at predetermined analyte concentrations. Determination of proteinuria showed the lowest proportion of false posi...

متن کامل

Interference in laboratory tests

Interference in clinical laboratory testing can create discrepancies in test results which can lead to patient harm.  In clinical chemistry, interference is defined as a cause of medically significant difference in the measurand test result due to another component or property of the sample. Interference by endogenous and exogenous substances with assays for clinical analytes is a common prob...

متن کامل

A model for assessing interference.

Most studies of analytical interference indicate the magnitude but not the type of interference. We developed a model for interference that assesses the magnitude of the following types of interference: independent of analyte concentration, dependent on analyte concentration, and a combination of the two. The experimental design for the model is an orthogonally arranged matrix with progressivel...

متن کامل

Characterization and mathematical correction of hemolysis interference in selected Hitachi 717 assays.

The effect of hemolysis on several assays performed with the Hitachi 717 was quantified by relating the amount of error to the concentration of hemoglobin. Hemolysis interference was judged clinically significant when analyte concentration varied by > 10% from the initial value. Hemolysis interference was significant for alkaline phosphatase, aspartate aminotransferase, alpha-amylase, bilirubin...

متن کامل

Interference with clinical laboratory analyses.

Interference by endogenous and exogenous substances with assays for clinical analytes is a common problem in laboratory medicine. For this review, we defined interference as "the effect of a substance present in the sample that alters the correct value of the result, usually expressed as concentration or activity, for an analyte." There are four major endogenous compounds that consistently inte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 11  شماره 

صفحات  -

تاریخ انتشار 1989