Concentric needle jitter on voluntary activated frontalis in 20 healthy subjects.

نویسندگان

  • João A Kouyoumdjian
  • Erik V Stålberg
چکیده

INTRODUCTION Normative data for jitter parameters using a disposable concentric needle have been described in a few studies. METHODS Jitter, expressed as the mean consecutive difference (MCD), was measured in the frontalis muscle in 20 subjects by voluntary contraction. RESULTS Mean MCD for individual studies (20, gaussian), all potentials (400, non-gaussian), and 18th highest value (20, gaussian) were 19.9 ± 2.9 μs, 19.9 ± 6.6 μs, and 26.9 ± 4.4 μs, respectively. CONCLUSION The suggested upper normal limit for mean MCD is 26 μs and for outliers is 36 μs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Jitter Values on Voluntary Active Periocular Muscles of Healthy Subjects with Conventional (37 mm) Concentric Needle Electrode.

INTRODUCTION The aim of this study was to re-evaluate jitter values of healthy subjects in whom pairs of single-fiber-like potentials were recorded from voluntary activated periocular muscles using a disposable 37-mm concentric needle electrode (CNE) with 2-kHz low-cut filtering. METHODS We reviewed the recordings of 129 subjects (85 women; 44 men; mean age, 43.8±15.3 years). The m. frontalis...

متن کامل

Reference values for jitter recorded by concentric needle electrodes in healthy controls: A multicenter study.

INTRODUCTION The aim of this study was to create reference values for jitter measured with concentric needle electrodes. METHODS Operators worldwide contributed recordings from orbicularis oculi (OO), frontalis (FR), and extensor digitorum (ED) muscles in healthy controls. Criteria for acceptable signal quality were agreed upon in advance. Fifteen or 20 recordings of acceptable quality from e...

متن کامل

Concentric needle jitter on stimulated frontalis and extensor digitorum in 20 myasthenia gravis patients.

INTRODUCTION Our objective was to study jitter parameters using a concentric needle electrode (CNE) in the extensor digitorum (ED) and frontalis (FR) muscles. METHODS Twenty myasthenia gravis (MG) patients, mean age 44.5 years, were studied. Percutaneous (FR) and intramuscular needle (ED) stimulation approaches were used. Jitter was expressed as the mean consecutive difference (MCD). The filt...

متن کامل

Stimulated jitter with concentric needle in 42 myasthenia gravis patients.

OBJECTIVE To estimate jitter parameters in myasthenia gravis in stimulated frontalis and extensor digitorum muscles using the concentric needle electrode. METHODS Forty-two confirmed myasthenia gravis patients, being 22 males (aged 45.6±17.2 years-old) were studied. Jitter was expressed as the mean consecutive difference (MCD). RESULTS MCD in extensor digitorum was 61.6 µs (abnormal in 85.7...

متن کامل

Concentric needle single fiber electromyography: normative jitter values on voluntary activated Extensor Digitorum Communis.

Single fiber electromyography (SFEMG) is the most sensitive clinical neurophysiological test for neuromuscular junction disorders, particularly myasthenia gravis. Normal values for jitter obtained with SFEMG electrode have been published, but there are few publications for concentric needle electrode (CNE). The aim of this study was to discuss the possibilities to analyse the jitter in CNE reco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Muscle & nerve

دوره 47 3  شماره 

صفحات  -

تاریخ انتشار 2013