Resolution of Dialyzer Membrane-Associated Thrombocytopenia with Use of Cellulose Triacetate Membrane: A Case Report

نویسندگان

  • Feyisayo Olafiranye
  • Win Kyaw
  • Oladipupo Olafiranye
چکیده

Blood and dialyzer membrane interaction can cause significant thrombocytopenia through the activation of complement system. The extent of this interaction determines the biocompatibility of the membrane. Although the newer synthetic membranes have been shown to have better biocompatibility profile than the cellulose-based membranes, little is known about the difference in biocompatibility between synthetic membrane and modified cellulose membrane. Herein, we report a case of a patient on hemodialysis who developed dialyzer-membrane-related thrombocytopenia with use of synthetic membrane (F200NR polysulfone). The diagnosis of dialyzer membrane-associated thrombocytopenia was suspected by the trend of platelet count before and after dialysis, and the absence of other possible causes of thrombocytopenia. We observed significant improvement in platelet count when the membrane was changed to modified cellulose membrane (cellulose triacetate). In patients at high risk for thrombocytopenia, the modified cellulose membrane could be a better alternative to the standard synthetic membranes during hemodialysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of dialyzer membrane materials on survival in chronic hemodialysis patients: Results from the annual survey of the Japanese Nationwide Dialysis Registry

BACKGROUND Little information is available regarding which type of dialyzer membrane results in good prognosis in patients on chronic hemodialysis. Therefore, we conducted a cohort study from a nationwide registry of hemodialysis patients in Japan to establish the association between different dialyzer membranes and mortality rates. METHODS We followed 142,412 patients on maintenance hemodial...

متن کامل

Influence of cellulose triacetate hemodialyzers on vancomycin pharmacokinetics.

This study was designed to evaluate the pharmacokinetics of vancomycin during hemodialysis with cellulose triacetate (CT) high-flux dialyzers and to assess the influence of membrane surface area on intradialytic clearance. In a randomized crossover fashion, the pharmacokinetics of vancomycin were evaluated during dialysis with the CT 110 and CT 190 membranes. Six hemodialysis patients received ...

متن کامل

Elimination of non-ionic contrast medium by hemodialysis in patients with impaired renal function.

The elimination rate of iohexol, a non-ionic contrast medium, from the blood by hemodialysis, and the elimination rate of iohexol by a dialyzer were studied in 15 patients with chronic renal dysfunction who required angiography or enhanced CT. The elimination rate of iohexol was 19.8% at 15 min after the start of hemodialysis, 30.6% after 30 min, 44.2% after 1 hour, 62.1% after 2 hours and 72.9...

متن کامل

The use of re-surgery in the treatment of teeth with severe sensitivity in the buccal mucous ‎membrane: A case report with 75 months follow-up

BACKGROUND AND AIM: A periapical endodontic surgery is an alternative treatment when teeth are not responding to conventional treatment and endodontic re-treatment.CASE REPORT: The following case report presents a clinical case of maxillary right and left central incisors with unsatisfying endodontic surgery and severe sensitivity in the buccal mucous membrane. Radiographic examination revealed...

متن کامل

Synthesis and Performance of Polyamide Forward Osmosis Membrane for Natural Organic Matter (NOM) Removal

Forward Osmosis (FO) polyamide thin-film composite membranes have been prepared by interfacial polymerization using commercial UF polyethersulfoneas membrane support. Different interfacial polymerization times (10s, 30s and 60s) in the organic solution containing trimesoyl chloride (TMC) at constant mphenylenediamine (MPD) concentration (2% w/v) were studied. The synthesized polyamide membranes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2011  شماره 

صفحات  -

تاریخ انتشار 2011