Comparison of cardiovascular magnetic resonance and single-photon emission computed tomography in women with suspected coronary artery disease from the Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease (CE-MARC) Trial.

نویسندگان

  • John P Greenwood
  • Manish Motwani
  • Neil Maredia
  • Julia M Brown
  • Colin C Everett
  • Jane Nixon
  • Petra Bijsterveld
  • Catherine J Dickinson
  • Stephen G Ball
  • Sven Plein
چکیده

BACKGROUND Coronary artery disease is the leading cause of death in women, and underdiagnosis contributes to the high mortality. This study compared the sex-specific diagnostic performance of cardiovascular magnetic resonance (CMR) and single-photon emission computed tomography (SPECT). METHODS AND RESULTS A total of 235 women and 393 men with suspected angina underwent CMR, SPECT, and x-ray angiography as part of the Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease (CE-MARC) study. CMR comprised adenosine stress/rest perfusion, cine imaging, late gadolinium enhancement, and magnetic resonance coronary angiography. Gated adenosine stress/rest SPECT was performed with (99m)Tc-tetrofosmin. For CMR, the sensitivity in women and men was similar (88.7% versus 85.6%; P=0.57), as was the specificity (83.5% versus 82.8%; P=0.86). For SPECT, the sensitivity was significantly worse in women than in men (50.9% versus 70.8%; P=0.007), but the specificities were similar (84.1% versus 81.3%; P=0.48). The sensitivity in both the female and male groups was significantly higher with CMR than SPECT (P<0.0001 for both), but the specificity was similar (P=0.77 and P=1.00, respectively). For perfusion-only components, CMR outperformed SPECT in women (area under the curve, 0.90 versus 0.67; P<0.0001) and in men (area under the curve, 0.89 versus 0.74; P<0.0001). Diagnostic accuracy was similar in both sexes with perfusion CMR (P=1.00) but was significantly worse in women with SPECT (P<0.0001). CONCLUSIONS In both sexes, CMR has greater sensitivity than SPECT. Unlike SPECT, there are no significant sex differences in the diagnostic performance of CMR. These findings, plus an absence of ionizing radiation exposure, mean that CMR should be more widely adopted in women with suspected coronary artery disease. CLINICAL TRIAL REGISTRATION URL http://www.controlled-trials.com. Unique identifier: ISRCTN77246133.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic accuracy of the core components of a multi-parametric cardiovascular magnetic resonance imaging protocol: a CE-MARC sub-study

Background The CE-MARC study was the largest prospective evaluation of the diagnostic accuracy of cardiovascular magnetic resonance (CMR) in coronary artery disease (CAD), demonstrating its superiority over single-photon emission computed tomography [1]. The trial adopted a multi-parametric protocol assessing ventricular function, myocardial perfusion, viability (with late gadolinium enhancemen...

متن کامل

Rationale and design of the Clinical Evaluation of Magnetic Resonance Imaging in Coronary heart disease 2 trial (CE-MARC 2): A prospective, multicenter, randomized trial of diagnostic strategies in suspected coronary heart disease

BACKGROUND A number of investigative strategies exist for the diagnosis of coronary heart disease (CHD). Despite the widespread availability of noninvasive imaging, invasive angiography is commonly used early in the diagnostic pathway. Consequently, approximately 60% of angiograms reveal no evidence of obstructive coronary disease. Reducing unnecessary angiography has potential financial saving...

متن کامل

A comparison of cardiovascular magnetic resonance and single photon emission computed tomography (SPECT) perfusion imaging in left main stem or equivalent coronary artery disease: a CE-MARC substudy

BACKGROUND Assessment of left main stem (LMS) stenosis has prognostic and therapeutic implications. Data on assessment of LMS disease by cardiovascular magnetic resonance (CMR) and single photon emission computed tomography (SPECT) are limited. CE-MARC is the largest prospective comparison of CMR and SPECT against quantitative invasive coronary angiography (QCA) for detection of coronary artery...

متن کامل

Comparative use of exercise tolerance testing, SPECT and CMR, alone and in combination, for the diagnosis of coronary heart disease in the CE-MARC study

Background Whilst exercise tolerance testing (ETT) has been a corner stone investigation for the diagnosis of patients with suspected angina, increasingly imaging techniques have gained prominence. We aimed to determine the diagnostic accuracy of ETT in the CE-MARC study population compared to single photon emission computed tomography (SPECT) and cardiovascular magnetic resonance (CMR) and to ...

متن کامل

Prognostic value of CMR and SPECT in suspected coronary heart disease: long term follow-up of the CE-MARC study

Background CE-MARC established the comparative diagnostic performance of cardiovascular magnetic resonance (CMR) and single photon emission computed tomography (SPECT) in patients with suspected coronary heart disease. However, there are no prospective, prognostic data comparing the two modalities in the same patient population. Our objective was to establish the comparative ability of CMR and ...

متن کامل