Evaluating the Effects of Field Size on Beam Homogeneity Coefficient in the Superficial Radiotherapy Machine Using Empirical Method and Simulation

نویسندگان

  • Hamed Babapour
  • Tayyeb Allahverdi Pourfallah
  • Ali Shabestani Monfared
  • Ali-Reza Shirazi
چکیده

Introduction Superficial X-ray therapy is one of the most important treatment methods in radiotherapy especially in the treatment of superficial skin lesions (Up to 300 kVp). Quality of the X-ray beam that can be expressed by Half-Value Layer (HVL), are important indices for this type of treatment effective energy of photon and Homogeneity Coefficient (HC). Materials and Methods The HC of the superficial X-ray machine at 180 kVp was determined by an experimental method and also by simulation (EGSnrc code) and the results were compared. The exposure after the first (0.5 mmCu) and second (1 mmCu) attenuation layers were measured by Farmer dosimeter for three different field sizes. The HC was derived from these experimental data and was compared with corresponding results acquired by EGSnrc code package. The BEAMnrc code was used to transport photons and electrons at exit level of the applicator, DOSXYZnrc code for calculation of absorbed dose in the phantom, and BEAMDP for drawing the output spectra. Results Results showed that the mean percentage difference of errors obtained by experimental data and simulation method is 3.3% and the average energy of output spectra in 180 kVp after passing through filters and attenuation layers increases to 15.3% to 25.4%. Conclusion The maximum percentage difference of errors for the applied methods is higher than analogous devolves elsewhere reports which could be due to setup parameters such as SSD and field size. However, the present method has the advantage of ease of setup and matching with clinical conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the Effects of Field Size on Beam Homogeneity Coefficient in the Superficial Radiotherapy Machine Using Empirical Method and Simulation

Introduction Superficial X-ray therapy is one of the most important treatment methods in radiotherapy especially in the treatment of superficial skin lesions (Up to 300 kVp). Quality of the X-ray beam that can be expressed by Half-Value Layer (HVL), are important indices for this type of treatment effective energy of photon and Homogeneity Coefficient (HC). Materials and Methods The HC of the s...

متن کامل

HVL evaluation of orthovoltage X-ray machine using EGSnrc code of simulation

Background: Making use of the orthovoltage machines in Radiotherapy, is one of the routine methods for the treatment of the superficial lesions. In this study, an important determinant of X-ray quality, the HVL (Half Value Layer), has been evaluated. Materials and Methods: The HVLs of a orthovoltage X-ray machine in 120 and 180 kVp are measured, using an empirical method, in which the HVLs are ...

متن کامل

Telecobalt Machine Beam Intensity Modulation with Aluminium Compensating Filter Using Missing Tissue Approach

Introduction: The present study aimed to generate intensity-modulated beams with Aluminium compensating filters for a conventional telecobalt machine based on the outputs of a treatment planning system (TPS) performing forward planning and cannot simulate directly the compensating filter. Materials and Methods: In order to achieve the beam intensity modulation during treatment planning with th...

متن کامل

Assessment of Neutron Contamination Originating from the Presence of Wedge and Block in Photon Beam Radiotherapy

Background: One of the main causes of induction of secondary cancer in radiation therapy is neutron contamination received by patients during treatment.Objective: In the present study the impact of wedge and block on neutron contamination production is investigated. The evaluations are conducted for a 15 MV Siemens Primus linear accelerator. Methods: Simulations were performed using MCNPX Monte...

متن کامل

Grid: A location dependent intensity modulated radiotherapy for bulky tumors

Background: An effective method for management of large and bulky malignant tumors. This treatment modality is also known as Specially Fractionated Radiation Therapy (SFRT). In this treatment technique a grid block converted the open radiation field into a series of pencil beams. Dosimetric characteristics of an external beam grid radiation field have been investigated using experimental and Mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012