Initial testing of a pixelated silicon detector prototype in proton therapy

نویسندگان

  • Andrew J. Wroe
  • Grant McAuley
  • Anthony V. Teran
  • Jeannie Wong
  • Marco Petasecca
  • Michael Lerch
  • James M. Slater
  • Anatoly B. Rozenfeld
چکیده

As technology continues to develop, external beam radiation therapy is being employed, with increased conformity, to treat smaller targets. As this occurs, the dosimetry methods and tools employed to quantify these fields for treatment also have to evolve to provide increased spatial resolution. The team at the University of Wollongong has developed a pixelated silicon detector prototype known as the dose magnifying glass (DMG) for real-time small-field metrology. This device has been tested in photon fields and IMRT. The purpose of this work was to conduct the initial performance tests with proton radiation, using beam energies and modulations typically associated with proton radiosurgery. Depth dose and lateral beam profiles were measured and compared with those collected using a PTW parallel-plate ionization chamber, a PTW proton-specific dosimetry diode, EBT3 Gafchromic film, and Monte Carlo simulations. Measurements of the depth dose profile yielded good agreement when compared with Monte Carlo, diode and ionization chamber. Bragg peak location was measured accurately by the DMG by scanning along the depth dose profile, and the relative response of the DMG at the center of modulation was within 2.5% of that for the PTW dosimetry diode for all energy and modulation combinations tested. Real-time beam profile measurements of a 5 mm 127 MeV proton beam also yielded FWHM and FW90 within ±1 channel (0.1 mm) of the Monte Carlo and EBT3 film data across all depths tested. The DMG tested here proved to be a useful device at measuring depth dose profiles in proton therapy with a stable response across the entire proton spread-out Bragg peak. In addition, the linear array of small sensitive volumes allowed for accurate point and high spatial resolution one-dimensional profile measurements of small radiation fields in real time to be completed with minimal impact from partial volume averaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

متن کامل

First test of a prototype CBM silicon detector system in a proton beam at GSI

In September 2008, the CBM collaboration performed the first essential test of two prototype detector systems in a 2.5 GeV proton beam at GSI. The experiment at the HTD beam line in Cave C comprised prototype micro-strip detectors of the Silicon Tracking System, and gas-electronmultiplier (GEM) detectors. The detectors were coupled to a self-triggering front-end electronics and data acquisition...

متن کامل

Initial studies on proton computed tomography using a silicon strip detector telescope

We report initial results of a feasibility study of Proton Computed Tomography and Proton Transmission Radiography for applications in proton therapy treatment planning and patient positioning. The aim of the study is to explore experimentally if PCT, which is based on the measurement of the specific energy loss of protons traversing tissues of different density, may be preferred to X-ray Compu...

متن کامل

A prototype direct-detection CCD for protein crystallography.

The fabrication and testing of a prototype deep-depletion direct-conversion X-ray CCD detector are described. The device is fabricated on 600 µm-thick high-resistivity silicon, with 24 × 24 µm pixels in a 4k × 4k pixel format. Calibration measurements and the results of initial protein crystallography experiments at the Cornell High Energy Synchrotron Source (CHESS) F1 beamline are described, a...

متن کامل

Development of a small-scale prototype of the GOSSIPO-2 chip in 0.13 μm CMOS technology

The GOSSIP (Gas On Slimmed Silicon Pixel) detector is a proposed alternative for silicon based pixel detectors. The Gossip Prototype (GOSSIPO) chip is being developed to serve as a prototype read-out chip for such a gas-filled detector. Thanks to the very low capacitance at the preamplifier input, the front-end of the chip demonstrates low-noise performance in combination with a fast peaking ti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017