Submitted to the Department of Aeronautics and Astronautics in Partial Fulfillment of the Degree of Master of Science in Aeronautics and Astronautics

نویسندگان

  • Robert Jeffrey Pascal
  • David W. Miller
  • ROBERT JEFFREY
چکیده

The use of a high-fidelity finite element model is investigated for the design and closedloop performance prediction of shaped and distributed sensors and actuators for structural acoustic control. Sensor and actuator design was found to be sensitive to nodeline discrepancies between the model and experiment caused by moderate manufacturing defects and/or boundary condition uncertainties. Relying on the finite element model for sensor shaping or distribution results in a slight difference between the desired and achieved sensor performance. The modeshape sensitivity is compounded when both the actuator and sensor are shaped or distributed, as is the case with a distributed sensuator design. This results in an unacceptable difference between the desired and achieved distributed sensuator performance. Since the advantages of shaping and distribution can be gained either at the system input (actuators) or output (sensors), modeshape information from a correlated analytic model should be used for one or the other, but not both. Experimental verification of critical modeshapes is also recommended to reduce sensor and actuator performance loss. The finite element model was also used to predict achievable closed-loop acoustic performance for various sensor and actuator pairs for transmission and reflection control. Since a finite element model is generally not accurate enough to be used as the basis for high performance compensator design, the predicted performance was compared to experimental results of compensators designed with an accurate data-fit model using the same control design methods. Good correlation was achieved between predicted and implemented results for linear behavior of the system. Finally, a comparison was made between a modally shaped PVDF sensor/PZT actuator design and a single wafer PZT sensuator. Both have desirable open-loop characteristics and comparable predicted performance. The predicted performance could not be implemented for the sensuator design due to a severe amplitude non-linearity. The PVDF sensor design is very linear, and the implemented performance slightly exceeded that predicted using the finite element model. Due to the implementation difficulties of the

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ionizing radiation induces ferroptosis in splenic lymphocytes of mice

Backgrounds: It remains unclear whether radiation-induced haemorrhage in the spleen causes iron accumulation, and subsequently, ferroptosis in splenic lymphocytes. In this study, we investigated the occurrence of ferroptosis in splenic lymphocytes of gamma-irradiated mice. Materials and Methods: Mice were subjected to gamma radiation from a 137Cs source. Iron, Ferroportin 1, and iron regulatory...

متن کامل

Development of methemoglobin-based biological dosimetry in gamma–irradiated mice

Background: A new biological dosimeter based on methemoglobin level was developed in this study. Materials and Methods: Methemoglobin level in erythrocytes from mice subjected to &gamma rays from a 60Co source was detected using the methemoglobin kit. The dose range was from 0.5 to 8 Gy and the dose rate was 0.5 Gy/min. Results: The results demonstrate that methemoglobin level increases with in...

متن کامل

Radiosensitizing effect of deferoxamine on human glioma cells

ABSTRACT Background: Tumor cells exhibit an increased requirement for iron to support their rapid proliferation. Deferoxamine (DFO), an iron chelator, has been reported to have anti-proliferative effects on cancer cells through induction of apoptosis and cell cycle arrest. X-rays also induce apoptosis and cell cycle arrest. However, limited information is available regarding the effect of iron...

متن کامل

Impacts of multiple-field irradiation and boron concentration on the treatment of boron neutron capture therapy for non-small cell lung cancer

Background: Boron neutron capture therapy (BNCT) is a radiotherapy that combines biological targeting and high linear energy transfer. A potential therapeutic approach for non-small cell lung cancer (NSCLC) is considered. However, dose in lung tumor is not homogeneous, and it will reduce the effect of BNCT treatment. In order to improve the dose distribution of BNCT, the multi-field irradiation...

متن کامل

Krylov Subspace Methods for Simultaneous Primal-Dual Solutions and Superconvergent Functional Estimates

Primal-Dual Solutions and Superconvergent Functional Estimates by James Lu Submitted to the Department of Aeronautics and Astronautics in partial fulfillment of the requirements for the degree of Master of Science in Aeronautics and Astronautics at the MASSACHUSETTS INSTITUTE OF TECHNOLOGY Sept 2002 © James Lu, MMII. All rights reserved. The author hereby grants to MIT permission to reproduce a...

متن کامل

Distributed Coordination and Control Experiments on a Multi-UAV Testbed

Distributed Coordination and Control Experiments on a Multi­UAV Testbed by Ellis T. King Bachelor of Engineering The State University of Buffalo, 2002 Submitted to the Department of Aeronautics and Astronautics in partial fulfillment of the requirements for the degree of Master of Science in Aeronautics and Astronautics at the MASSACHUSETTS INSTITUTE OF TECHNOLOGY September 2004 � Massachusetts...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009