Radiation-associated circulatory disease mortality in a pooled analysis of 77,275 patients from the Massachusetts and Canadian tuberculosis fluoroscopy cohorts

نویسندگان

  • Van Tran
  • Lydia B. Zablotska
  • Alina V. Brenner
  • Mark P. Little
چکیده

High-dose ionising radiation is associated with circulatory disease. Risks associated with lower-dose (<0.5 Gy) exposures remain unclear, with little information on risk modification by age at exposure, years since exposure or dose-rate. Tuberculosis patients in Canada and Massachusetts received multiple diagnostic x-ray fluoroscopic exposures, over a wide range of ages, many at doses <0.5 Gy. We evaluated risks of circulatory-disease mortality associated with <0.5 Gy radiation exposure in a pooled cohort of 63,707 patients in Canada and 13,568 patients in Massachusetts. Under 0.5 Gy there are increasing trends for all circulatory disease (n = 10,209; excess relative risk/Gy = 0.246; 95% CI 0.036, 0.469; p = 0.021) and for ischaemic heart disease (n = 6410; excess relative risk/Gy = 0.267; 95% CI 0.003, 0.552; p = 0.048). All circulatory-disease and ischaemic-heart-disease risk reduces with increasing time since exposure (p < 0.005). Over the entire dose range, there are negative mortality dose trends for all circulatory disease (p = 0.014) and ischaemic heart disease (p = 0.003), possibly due to competing causes of death over this dose interval.These results confirm and extend earlier findings and strengthen the evidence for circulatory-disease mortality radiation risk at doses <0.5 Gy. The limited information on well-known lifestyle/medical risk factors for circulatory disease implies that confounding of the dose trend cannot be entirely excluded.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patient dose values during interventional cardiology examinations in Yazd hospital, Iran

Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...

متن کامل

Circulatory Disease Mortality in a Canadian Occupational Cohort with Low Dose Exposure to Ionizing Radiation

Exposure to high doses of ionizing radiation, such as those received during radiotherapy, leads to increased risk of circulatory diseases.. Emerging evidence of excess risks of circulatory diseases after exposure to doses well below those considered previously as safe warrants epidemiological studies of populations exposed to low levels of ionizing radiation. The purpose of our study was to eva...

متن کامل

سل ستون فقرات اولین تظاهر بالینی بیمار مبتلا به میلوم متعدد: گزارش موردی

Background: Patients with hematologic malignancies are at risk of advanced tuberculosis. The prevalence of tuberculosis between these patients is 2.1- 2.6 percent. The cellular immune deficiency caused by hematologic malignancies and or its treatment increases the risk of tuberculosis in these patients. Multiple Myeloma is malignant proliferations of plasma cells that involves different classes...

متن کامل

Original Contribution Potential IncreasedRisk of Ischemic Heart DiseaseMortalityWith Significant Dose Fractionation in the Canadian Fluoroscopy Cohort Study

Risks of noncancer causes of death, particularly cardiovascular disease, associated with exposures to high-dose ionizing radiation, are well known. Recent studies have reported excess risk in workers who are occupationally exposed to low doses at a low dose rate, but the risks of moderately fractionated exposures, such as occur during diagnostic radiation procedures, remain unclear. The Canadia...

متن کامل

Evaluation of Patients’ Exposure during Angiography and Angioplasty Procedures in the Angiography Department of Shahid Madani Hospital in Tabriz

Introduction: Coronary angiography and angioplasty procedures lead to significant radiation exposure of patients. In the current study, the average radiation dose to patients during angiography in the Angiography Department of Shahid-Madani Hospital was determined. Materials and Methods: An image intensifier based angiography unit (Philips BH 3000) was used for angiography procedures. The accur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017