Influence of Orbital Implant Length and Diameter on Stress Distribution: A Finite Element Analysis

نویسندگان

  • Zhang Xing
  • Ling Song Chen
  • Wei Peng
  • Ling Jian Chen
چکیده

PURPOSE A mathematical simulation of stress distribution around orbital implants was used to determine which length and diameter of implants would be best to dissipate stress. METHODS An integrated system for computed tomography data was utilized to create a 3-dimensional model of craniofacial structures. The model simulated implants placed in the 7, 11, and 12 o'clock positions of the orbital rim. A load of 2 N was applied to the model along the long axis of the implant (model 1) and an angle of 45° with the long axis of the implant (model 2). A model simulating an implant with a diameter of 3.75 mm and lengths of 3, 4, 6, 8, and 10 mm was developed to investigate the influence of the length factor. The influence of different diameters was modeled using implants with a length of 6 mm and diameters of 3.0, 3.75, 4.2, 5.0, and 6.0 mm. Values of von Mises equivalent stress at the implant-bone interface were computed using the finite element analysis for all variations. RESULTS The elements exposed to the maximum stress were located around the root of the orbital implant in model 1 or between the neck and the first thread of the orbital implant in model 2. An increase in the orbital implant diameter led to a decrease in the maximum von Mises equivalent stress values. In model 1, the reductions were 45.2% (diameter of 3.0-3.75 mm), 25.3% (diameter of 3.75-4.2 mm), 17.2% (diameter of 4.2-5.0 mm), and 5.4% (diameter of 5.0-6.0 mm). In model 2, the reductions of the maximum stress values were 51.9%, 35.4%, 19.7%, and 8.1% respectively. However, the influence of orbital implant length was not as pronounced as that of diameter. In model 1, the reductions were 28.8% (length of 3-4 mm), 19.2% (length of 4-6 mm), 9.6% (length of 6-8 mm), and 4.3% (length of 8-10 mm). In model 2, the reductions of the maximum stress values were 35.5%, 21.1%, 10.9%, and 5.4% respectively. CONCLUSIONS An increase in the implant diameter decreased the maximum von Mises equivalent stress around the orbital implant more than an increase in the implant length. From a biomechanical perspective, the optimum choice was an orbital implant with no less than 4.2 mm diameter allowed by the anatomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The axisymmetric computational study of a femoral component to analysis the effect of titanium alloy and diameter variation.

This work presents a numerical approach in order to predict the influence of implant material stiffness in a femoral component design when submitted in compression. The implant success depends on the transferred load to the neighboring bone. The finite element method can be used to analysis the stress and strain distribution in the femoral component allowing to improve the implant selection. Fo...

متن کامل

Evaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method

 longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...

متن کامل

Influence of Implant Length and Diameter, Bicortical Anchorage, and Sinus Augmentation on Bone Stress Distribution: Three-Dimensional Finite Element Analysis.

PURPOSE Clarification of the protocol for using short implants is required to enable widespread use of short implants as an available treatment option. The purpose of this study was to investigate the influences of implant length and diameter, bicortical anchorage, and sinus augmentation on peri-implant cortical bone stress by three-dimensional finite element analysis. MATERIALS AND METHODS F...

متن کامل

Effect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis

Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...

متن کامل

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis Dr. A. Fazel * - Dr. SH. A. Alai ** - Dr. M. Rismanchian *** *Associate Professor of Prosthodontics Dept., Faculty of Dentistry and Dental Research Center, Tehran University / Medical Sciences. **Assistant Professor of Prosthodontics Dept., Faculty of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2017