The clearance of protein-bound solutes by hemofiltration and hemodiafiltration.

نویسندگان

  • Timothy W Meyer
  • Jason L Walther
  • Maria Enrica Pagtalunan
  • Andres W Martinez
  • Ali Torkamani
  • Patrick D Fong
  • Natalie S Recht
  • Channing R Robertson
  • Thomas H Hostetter
چکیده

BACKGROUND Hemofiltration in the form of continuous venovenous hemofiltration (CVVH) is increasingly used to treat acute renal failure. Compared to hemodialysis, hemofiltration provides high clearances for large solutes but its effect on protein-bound solutes has been largely ignored. METHODS Standard clinical systems were used to remove test solutes from a reservoir containing artificial plasma. Clearances of the protein-bound solutes phenol red (C(PR)) and indican (C(IN)) were compared to clearances of urea (C(UREA)) during hemofiltration and hemodiafiltration. A mathematical model was developed to predict clearances from values for plasma flow Q(p), dialysate flow Q(d), ultrafiltration rate Q(f), filter size and the extent of solute binding to albumin. RESULTS When hemofiltration was performed with Q(p) 150 mL/min and Q(f) 17 mL/min, clearance values were C(PR) 1.0 +/- 0.1 mL/min; C(IN) 3.7 +/- 0.5 mL/min; and C(UREA) 14 +/- 1 mL/min. The clearance of the protein-bound solutes was approximately equal to the solute-free fraction multiplied by the ultrafiltration rate corrected for the effect of predilution. Addition of Q(d) 42 mL/min to provide HDF while Q(p) remained 150 mL/min resulted in proportional increases in the clearance of protein-bound solutes and urea. In contrast, the clearance of protein-bound solutes relative to urea increased when hemodiafiltration was performed using a larger filter and increasing Q(d) to 300 mL/min while Q(p) was lowered to 50 mL/min. The pattern of observed results was accurately predicted by mathematical modeling. CONCLUSION In vitro measurements and mathematical modeling indicate that CVVH provides very limited clearance of protein-bound solutes. Continuous venous hemodiafiltration (CVVHDF) increases the clearance of protein-bound solutes relative to urea only when dialysate flow rate and filter size are increased above values now commonly employed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Release of uremic retention solutes from protein binding by hypertonic predilution hemodiafiltration.

Protein-bound uremic retention solutes accumulate in patients suffering from chronic kidney disease, and the removal of these solutes by hemodialysis is hampered. Therefore, we developed a dialysis technique where the protein-bound uremic retention solutes are removed more efficiently under high ionic strength. Protein-bound uremic solutes such as phenylacetic acid, indoxyl sulfate, and p-cresy...

متن کامل

Screening of UV-absorbing solutes in uremic serum by reversed phase HPLC--change of blood levels in different therapies.

In order to screen UV-absorbing solutes in large numbers of uremic serum samples, an automated liquid chromatographic method was developed. The method proved to be reliable and reproducible in more than 500 analyses. HPLC separation was performed using gradient elution on a 25-cm Ultrasphere Octyl reversed phase column, with 5 microns particles. Characteristic profiles for the uremic state were...

متن کامل

Protein-leaking membranes for hemodialysis: a new class of membranes in search of an application?

A new class of membranes that leak protein has been developed for hemodialysis. These membranes provide greater clearances of low molecular weight proteins and small protein-bound solutes than do conventional high-flux dialysis membranes but at the cost of some albumin loss into the dialysate. Protein-leaking membranes have been used in a small number of clinical trials. The results of these tr...

متن کامل

Convective therapies versus low-flux hemodialysis for chronic kidney failure: a meta-analysis of randomized controlled trials.

BACKGROUND Although convective therapies have gained popularity for the optimal removal of uremic solutes, their benefits and potential risks have not been fully elucidated. We conducted a meta-analysis of all randomized controlled trials comparing convective therapies with low-flux hemodialysis in patients with chronic kidney failure. METHODS We performed a literature search using MEDLINE (i...

متن کامل

Hemofiltration or hemodialysis for acute kidney injury?

The optimal choice of modality for acute renal replacement therapy is unclear at present. Diffusive therapy (hemodialysis) removes small solutes mainly, whereas convective therapies (hemofiltration and hemodiafiltration) may also eliminate larger molecules such as myoglobin or cytokines. Conversely, convective therapies might predispose patients to filter clotting and thus increased costs. A sy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kidney international

دوره 68 2  شماره 

صفحات  -

تاریخ انتشار 2005