Removal of Silicone Oil From Intraocular Lens Using Novel Surgical Materials.

نویسندگان

  • Eleftherios I Paschalis
  • Dean Eliott
  • Demetrios G Vavvas
چکیده

PURPOSE To design, fabricate, and evaluate novel materials to remove silicone oil (SiO) droplets from intraocular lenses (IOL) during vitreoretinal surgery. METHODS Three different designs were fabricated using soft lithography of polydimethylsiloxane (PDMS), three-dimensional (3D) inverse PDMS fabrication using water dissolvable particles, and atomic layer deposition (ALD) of alumina (Al2O3) on surgical cellulose fibers. Laboratory tests included static and dynamic contact angle (CA) measurements with water and SiO, nondestructive x-ray microcomputer tomography (micro-CT), and microscopy. SiO removal was performed in vitro and ex vivo using implantable IOLs and explanted porcine eyes. RESULTS All designs exhibited enhanced hydrophobicity and oleophilicity. Static CA measurements with water ranged from 131° to 160° and with SiO CA approximately 0° in 120 seconds following exposure. Nondestructive x-ray analysis of the 3D PDMS showed presence of interconnected polydispersed porosity of 100 to 300 μm in diameter. SiO removal from IOLs was achieved in vitro and ex vivo using standard 20-G vitrectomy instrumentation. CONCLUSION Removal of SiO from IOLs can be achieved using materials with lower surface energy than that of the IOLs. This can be achieved using appropriate surface chemistry and surface topography. Three designs, with enhanced hydrophobic properties, were fabricated and tested in vitro and ex vivo. All materials remove SiO within an aqueous environment. Preliminary ex vivo results were very promising, opening new possibilities for SiO removal in vitreoretinal surgeries. TRANSLATIONAL RELEVANCE This is the first report of an instrument that can lead to successful removal of SiO from the surface of IOL. In addition to the use of this instrument/material in medicine it can also be used in the industry, for example, retrieval of oil spills from bodies of water.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Visual Outcomes and Refractive Status after Combined Silicone Oil Removal/Cataract Surgery with Intraocular Lens Implantation

Purpose To evaluate refractive status and identify predictors of surgical success following a combined silicone oil removal/cataract surgery with intraocular lens (IOL) implantation procedure. Methods In this single-armed, retrospective study, we reviewed patients who underwent vitreoretinal surgery followed by a combined silicone oil removal/cataract surgery procedure between 2009 and 2013. ...

متن کامل

Refractive Change Caused Silicone Oil Adhesion to the Intraocular Lens Following Nd:YAG Posterior Capsulotomy

A 32-year-old female who had undergone the silicone oil removal procedure presented with visual disturbance in her left eye. Several months previous, she had cataract surgery in a private clinic, and a month later she had a Nd:YAG laser procedure for posterior capsulotomy. The slit-lamp examination revealed silicone oil droplets that had adhered to the intraocular lens where the posterior capsu...

متن کامل

Intraoperative biometry for intraocular lens (IOL) power calculation at silicone oil removal.

PURPOSE Cataract development is common following retinal detachment surgery that necessitates silicone oil injection. Intraocular lens (IOL) power calculation in the presence of silicone oil is challenging for many reasons. The authors evaluated the accuracy of intraoperative biometry during cataract surgery in silicone-filled eyes. METHODS Twelve cases of cataract in eyes filled with silicon...

متن کامل

Interaction with intraocular lens materials: does heavy silicone oil act like silicone oil?

PURPOSE To determine the interaction of heavy silicone oil with various intraocular lens (IOL) materials and whether heavy silicone oil covers the silicone IOL optic as silicone oil does. SETTING Department of Ophthalmology, Dokuz Eylul University, Izmir, Turkey. METHODS The study group comprised 5 poly(methyl methacrylate) (PMMA) IOLs, 4 foldable silicone IOLs, 5 foldable hydrophilic acryl...

متن کامل

Silicone oil removal. I. The effect on the complications of silicone oil.

The results of a retrospective study of the effects of silicone oil removal from 85 eyes in 85 patients are reported. Pars plana vitrectomy and fluid/silicone oil exchange had been undertaken for retinal detachments associated with giant retinal tears or with proliferative vitreoretinopathy in all cases. Clinically significant cataract developed in 60% of lenses that were clear at the time of o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Translational vision science & technology

دوره 3 5  شماره 

صفحات  -

تاریخ انتشار 2014