Comparing the Performance of Two Gamma Cameras

نویسنده

  • Niels Rossing
چکیده

The performance of most—if not all—gamma cameras on the market is satisfactory for static imag ing at low count rates. CT scanning, however, will reduce the need for such static studies, with bone scintigraphy as one of the few possible exceptions. In the future the main load will lie on dynamic func tional studies. Many such procedures—in particu lar radiospirometry, radiocardiography and regional cerebral blood flow—demand such high count rates that the capabilities of the cameras become critical, and differences between their performances become evident (1—4).Currently, therefore, the performance at high count rates must be an essential criterion for the choice of a gamma camera. The main objective of this study, accordingly, is to devise relevant methods of testing such perform

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nuclear cardiology in Iran in 2002 [Persian]

Aim: Few nuclear cardiology surveys were published in the literature, mostly from developed countries. The aim of this study is to perform a nuclear cardiology survey in Iran. This may lead to better decision making and programming. Methods and Materials: A questionnaire was sent by mail or e-mail to all nuclear medicine centers in Iran asking for details of nuclear cardiology practice in...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

Observed intercamera variability in clinically relevant performance characteristics for Siemens Symbia gamma cameras

We conducted an evaluation of the intercamera (i.e., between cameras) variability in clinically relevant performance characteristics for Symbia gamma cameras (Siemens Medical Solutions, Malvern, PA) based on measurements made using nine separate systems. The significance of the observed intercamera variability was determined by comparing it to the intracamera (i.e., within a single camera) vari...

متن کامل

Comparative assessment of the accuracy of maximum likelihood and correlated signal enhancement algorithm positioning methods in gamma camera with large square photomultiplier tubes

Introduction: The gamma cameras, based on scintillation crystal followed by an array of photomultiplier tubes (PMTs), play a crucial role in nuclear medicine. The use of square PMTs provides the minimum dead zones in the camera. The camera with square PMTs also reduces the number of PMTs relative to the detection area. Introduction of a positioning algorithm to improve the spat...

متن کامل

A scheme for assessing the performance characteristics of small field-of-view gamma cameras.

Existing protocols for assessing the performance characteristics of large field-of-view (LFOV) gamma cameras can be inappropriate and require modification for use with small field-of-view (SFOV) gamma camera systems. This communication proposes a generic scheme suitable for evaluating the performance characteristics of SFOV gamma cameras, based on modifications to the standard procedures of NEM...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006