Total percutaneous endovascular aneurysm repair with the dual 6-F Perclose-AT preclosing technique: a case-control study.
نویسندگان
چکیده
PURPOSE To determine the safety and efficacy of total percutaneous access closure for endovascular aortic aneurysm repair with a suture-mediated preclosing technique. MATERIALS AND METHODS One hundred thirty-two femoral access sites in 70 patients who underwent endovascular aortic aneurysm repair were closed percutaneously with off-label use of two F-6 Perclose AT devices preapplied at a 90 degrees angle. Femoral access sizes ranged from 12 to 24 F. Technical success, complications, and procedure and access closure times were evaluated. Follow-up with computed tomography and/or magnetic resonance imaging was scheduled at 1-4 days and 3, 6, and 12 months and used to obtain groin hematoma and scar severity scores (grades 1-3). Data were compared with those from a cohort of 67 patients who underwent endovascular aortic aneurysm repair with surgical femoral cutdown. RESULTS Technical success was achieved with the preclosing technique in 127 of the 132 arteries (96.2%). Two to four closure devices were used per groin. Five technical failures were managed intraoperatively with surgical suture. There was no access-related mortality and no late groin complications. The mean procedure duration was 91 minutes +/- 32, and the mean access closure time was 12 minutes +/- 9. For surgical management, the mean procedure time was 153 minutes +/- 112 (P < .05), and the mean closure time was 12 minutes +/- 13 (not statistically significant). Hematoma severity score at 1-4 days was 1.8 for total percutaneous endovascular aneurysm repair and 2.1 for surgical closure. Scar severity scores at 3, 6, and 12 months were 1.1, 1.0, and 1.0 for total percutaneous endovascular aneurysm repair and 2.4, 2.4, and 2.3 for surgical management, respectively. CONCLUSIONS Total percutaneous endovascular aneurysm repair with a dual 6-F-Perclose preclosing technique is safe and effective. Compared with femoral cutdown, there are fewer late groin complications and scar tissue formation is less severe.
منابع مشابه
Canadian experience with percutaneous endovascular aneurysm repair: short-term outcomes.
BACKGROUND To decrease the morbidity associated with cut-downs during endovascular aneurysm repair, some authors have suggested the totally percutaneous endovascular repair (PEVAR). The goal of this report is to evaluate and describe our centre's experience with the total percutaneous endovascular aneurysm repair (PEVAR) for aortic abdominal aneurysm (AAA). METHODS We performed a retrospectiv...
متن کاملSuccessful endovascular coiling of a ruptured internal iliac artery aneurysm: a case report
Ruptured internal iliac artery aneurysms (IIAA) are extremely rare, and the repair can be challenging. This case reports described an 83-year-old patient who presented at our Emergency Department with acute abdominal pain based on a ruptured IIAA. He refused open repair and only wanted to be treated as minimally invasive as possible. Therefore endovascular embolization of the IIAA was performed...
متن کاملPercutaneous endovascular repair of infrarenal abdominal aortic aneurysms: a feasibility study.
BACKGROUND Endovascular grafting has markedly reduced the invasiveness of the treatment of abdominal aortic aneurysms. By using a modification of technique for available closure devices, we have been able to achieve percutaneous repair of aneurysms. This study reviewed our initial experience with this technique. METHODS Demographics and background data from patients undergoing endovascular re...
متن کاملAn Aortoenteric Fistula Arising after Endovascular Management of a Mycotic Abdominal Aortic Aneurysm Complicated with a Psoas Abscess
Mycotic aortic aneurysms account for 1–3% of all aortic aneurysms. The management of this disease is controversial. Since open surgical repair is associated with high morbidity and mortality rates, endovascular aneurysm repair is an alternative treatment method with promising early and midterm outcomes, although its long-term durability is unknown.Secondary aortoenteric fistulas may occur iatro...
متن کاملPredictors and Treatments of Proglide-Related Complications in Percutaneous Endovascular Aortic Repair
PURPOSE To investigate the predictors and treatment of the 6-Fr Perclose Proglide-related complications (PRC) in percutaneous endovascular aortic repair (pEVAR). METHODS We retrospectively analyzed the PRC after pEVAR for the treatment of aortic aneurysm or dissection in our center from December 2012 to November 2013. Procedure success was defined as effective functioning of the two devices a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of vascular and interventional radiology : JVIR
دوره 20 10 شماره
صفحات -
تاریخ انتشار 2009