Pressure recording analytical method for measuring cardiac output in critically ill children: a validation study.

نویسندگان

  • R Saxena
  • A Durward
  • N K Puppala
  • I A Murdoch
  • S M Tibby
چکیده

BACKGROUND Pressure recording analytical method (PRAM) is a novel, arterial pulse contour-based method for measuring cardiac output (CO). Validation studies of PRAM in children are few, and have not assessed both absolute accuracy and ability to track changes in CO across a broad case mix. We aimed to compare CO as measured by PRAM with that using a transpulmonary dilution method in a cohort of critically ill children. METHODS Forty-eight, mechanically ventilated children with a median (inter-quartile) weight of 10.7 (5.5-15) kg with arterial and central venous catheters in situ were studied. CO was measured simultaneously using PRAM and the comparator method, transpulmonary ultrasound dilution (UD). Measurements were repeated before and after therapeutic interventions that were intended to augment CO (e.g. fluid bolus). RESULTS In total, 210 paired measurements were compared. The mean (sd) CO was 1.9 (1.2) litre min(-1) with UD when compared with 1.92 (0.5) litre min(-1) using PRAM. The mean bias was 0.02 litre min(-1) with wide limits of agreement: ± 2.21 litre min(-1), giving a percentage error of 116%. The concordance between PRAM and UD for measuring changes in CO was also poor, with only 37% of measurements falling within the pre-defined polar plot limits of ±30°. CONCLUSIONS There is an unacceptably poor agreement between UD and PRAM. We do not recommend the use of PRAM for measuring CO in critically ill children with the current algorithm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Lack of agreement between pulmonary arterial thermodilution cardiac output and the pressure recording analytical method in postoperative cardiac surgery patients.

BACKGROUND Pulse-contour analysis method (PCM) cardiac output (CO) monitors are increasingly used for CO monitoring during anaesthesia and in the critically ill. Very recently, several systems have been introduced that do not need calibration; among them the pressure recording analytical method (PRAM). Sparse data comparing the accuracy of the PRAM-CO with conventional thermodilution CO (ThD-CO...

متن کامل

Most Care®: a minimally invasive system for hemodynamic monitoring powered by the Pressure Recording Analytical Method (PRAM)

Invasive hemodynamic monitoring is a cornerstone of the care of critically ill and hemodynamically unstable patients in both intensive care units and operating rooms. The assessment of cardiac output by means of the pulmonary artery catheter has been considered the clinical gold standard. Nevertheless, several concerns have been raised regarding its invasiveness, usefulness, and associated comp...

متن کامل

A preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs

BACKGROUND Haemodynamic variations normally occur in anaesthetized animals, in relation to the animal status, administered drugs, sympathetic and parasympathetic tone, fluid therapy and surgical stimulus. The possibility to measure some cardiovascular parameters, such as cardiac output (CO), during anaesthesia would be beneficial for both the anaesthesia management and its outcome. New techniqu...

متن کامل

The "systolic volume balance" method for the noninvasive estimation of cardiac output based on pressure wave analysis.

Cardiac output (CO) monitoring is essential for the optimal management of critically ill patients. Several mathematical methods have been proposed for CO estimation based on pressure waveform analysis. Most of them depend on invasive recording of blood pressure and require repeated calibrations, and they suffer from decreased accuracy under specific conditions. A new systolic volume balance (SV...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 110 3  شماره 

صفحات  -

تاریخ انتشار 2013