Simultaneous determination of xylazine, free morphine, codeine, 6-acetylmorphine, cocaine and benzoylecgonine in postmortem blood by UPLC-MS-MS.

نویسندگان

  • Kazandra Ruiz-Colón
  • María A Martínez
  • Luz A Silva-Torres
  • Carlos Chavez-Arias
  • Margarita Meléndez-Negrón
  • María S Conte-Miller
  • Joseph Bloom-Oquendo
چکیده

Xylazine, a veterinary sedative, has been found as an adulterant of heroin in street drugs in Puerto Rico. It was found in combination with free morphine and 6-acetylmorphine, codeine, cocaine and benzoylecgonine in postmortem cases at the Puerto Rico Institute of Forensic Sciences (PRIFS). Xylazine is not approved for human use because it has been proven harmful. Currently, three separate analyses are required to determine all the aforementioned drugs at the PRIFS's toxicology laboratory. To reduce analysis time consumption, sample volume, run time, sample preparation and cost, a high-throughput ultra-high-pressure liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous quantification of xylazine, free morphine, 6-acetylmorphine, codeine, cocaine and benzoylecgonine in 0.25 mL postmortem blood by protein precipitation, fulfilling confirmation criteria with three transitions for each compound with acceptable relative ion intensities. Linearity was established between 10-1,000 ng/mL. Total run time was 2.5 min. Limit of detection was 1 ng/mL for cocaine and xylazine, 2 ng/mL for 6-acetylmorphine and 10 ng/mL for free morphine, codeine and benzoylecgonine. The intra-day and inter-day precision and accuracy was less than 15.6%. Process efficiencies ranged from 35.9 to 123.4% and recoveries from 59.9 to 110.1%. The developed method was successfully applied to casework.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Screening for drugs of abuse in hair with ion spray LC-MS-MS.

Analyzing hair for many substances can be tedious and expensive, and a rapid screening method should prove helpful. Generally, screening has been performed using immunological tests, mainly in workplace drug testing, where the number of samples has been high. The aim of this study was to develop an LC-MS-MS method for the simultaneous analysis of several drugs of abuse in human hair as an alter...

متن کامل

Comprehensive Automation of the SPE-GC/MS Analysis of Opioids, Cocaine and Metabolites from Serum and Other Matrices

Analyzing blood serum for opioids, cocaine and metabolites is a routine task in forensic laboratories. The most commonly used methods involve several manual or partly-automated sample preparation steps such as protein precipitation, solid phase extraction, evaporation and derivatization followed by GC/MS or LC/MS determination. In this study a comprehensively automated method is compared with a...

متن کامل

Quantitative determination of amphetamines, cocaine, and opiates in human hair by gas chromatography/mass spectrometry.

Hair of young subjects (N = 36) suspected for drug abuse was analysed for morphine, codeine, heroin, 6-acetylmorphine, cocaine, methadone, amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), and 3,4-methylenedioxyethylamphetamine (MDEA). The analysis of morphine, codeine, heroin, 6-acetylmorphine, cocaine, and methadone in hair included i...

متن کامل

Sweat testing in opioid users with a sweat patch.

For many years, toxicologists have detected the presence of drugs of abuse in biological materials using blood or urine. In recent years, remarkable advances in sensitive analytical techniques have enabled the analysis of drugs in unconventional samples such as sweat. In a study conducted in a detoxification center, sweat patches were applied to 20 known heroin abusers. Subjects wore the patch ...

متن کامل

Analytical evaluation of four on-site oral fluid drug testing devices.

The use of oral fluid (OF) as an alternative matrix for the detection of drugs of abuse has increased over the last decade, leading to the need for a rapid, simple, and reliable on-site OF testing device. Four on-site OF drug testing devices (Dräger DrugTest 5000, Cozart DDS, Mavand Rapid STAT, and Innovacon OrAlert) were evaluated on 408 volunteers at drug treatment centers. UPLC-MS-MS results...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 36 5  شماره 

صفحات  -

تاریخ انتشار 2012