Percutaneous edge-to-edge mitral valve repair in high-surgical-risk patients: do we hit the target?
نویسندگان
چکیده
OBJECTIVES This study sought to assess the feasibility and safety of percutaneous edge-to-edge mitral valve (MV) repair in patients with an unacceptably high operative risk. BACKGROUND MV repair for mitral regurgitation (MR) can be accomplished by use of a clip that approximates the free edges of the mitral leaflets. METHODS All patients were declined for surgery because of a high logistic EuroSCORE (>20%) or the presence of other specific surgical risk factors. Transthoracic echocardiography was performed before and 6 months after the procedure. Differences in New York Heart Association (NYHA) functional class, quality of life (QoL) using the Minnesota questionnaire, and 6-min walk test (6-MWT) distances were reported. RESULTS Fifty-five procedures were performed in 52 patients (69.2% male, age 73.2 ± 10.1 years, logistic EuroSCORE 27.1 ± 17.0%). In 3 patients, partial clip detachment occurred; a second clip was placed successfully. One patient experienced cardiac tamponade. Two patients developed inguinal bleeding, of whom 1 needed surgery. Six patients (11.5%) died during 6-month follow-up (5 patients as a result of progressive heart failure and 1 noncardiac death). The MR grade before repair was ≥3 in 100%; after 6 months, a reduction in MR grade to ≤2 was present in 79% of the patients. Left ventricular (LV) end-diastolic diameter, LV ejection fraction, and systolic pulmonary artery pressure improved significantly. Accompanied improvements in NYHA functional class, QoL index, 6-MWT distances, and log N-terminal pro-B-type natriuretic peptide were observed. CONCLUSIONS In a high-risk population, MR reduction can be achieved by percutaneous edge-to-edge valve repair, resulting in LV remodeling with improvement of functional capacity after 6 months.
منابع مشابه
The predictive value of conventional surgical risk scores for periprocedural mortality in percutaneous mitral valve repair
BACKGROUND Surgical risk scores are used to identify high-risk patients for surgical mitral valve repair. There is no scoring system to estimate the mortality risk for patients undergoing percutaneous treatment. The aim of this analysis is to evaluate the predictive value of the EuroSCOREs and the Society of Thoracic Surgeons Predicted Risk of Mortality Score (STS) for periprocedural mortality ...
متن کاملSurgical revision after percutaneous mitral valve repair by edge-to-edge device: when the strategy fails in the highest risk surgical population.
OBJECTIVES Percutaneous edge-to-edge devices for non-surgical repair of mitral valve regurgitation are under clinical evaluation in high-risk patients deemed not suitable for conventional surgery. To address guidelines for initial therapy decision, we here report on 13 cases of surgery after failed percutaneous edge-to-edge mitral valve repair or attempted repair, and discuss methodology and pr...
متن کاملThe evolution from surgery to percutaneous mitral valve interventions: the role of the edge-to-edge technique.
The edge-to-edge technique is a versatile procedure for mitral valve repair. Its technical simplicity has been the prerequisite for the development of a number of transcatheter technologies to perform percutaneous mitral valve repair. The evolution from a standard open heart surgical to percutaneous procedure involved the application of the technique in minimally invasive robotic surgery and di...
متن کاملSelecting patients for percutaneous mitral valve therapy
Patients with severe symptomatic mitral regurgitation benefit from correction of mitral regurgitation. Surgical mitral valve repair or replacement is the current standard of care for these patients. However, high risk of surgery in many of these patients, lack of universal expertise for mitral valve repair and moderate long-term success in correcting functional mitral regurgitation are some of ...
متن کاملPercutaneous mitral valve repair for mitral regurgitation in high-risk patients: results of the EVEREST II study.
BACKGROUND The EVEREST II (Endovascular Valve Edge-to-Edge REpair STudy) High-Risk registry and REALISM Continued Access Study High-Risk Arm are prospective registries of patients who received the MitraClip device (Abbott Vascular, Santa Clara, California) for mitral regurgitation (MR) in the United States. OBJECTIVES The purpose of this study was to report 12-month outcomes in high-risk pati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular interventions
دوره 5 1 شماره
صفحات -
تاریخ انتشار 2012