Stability enhancement by joint phase measurements in a single cold atomic fountain
نویسندگان
چکیده
We propose a method of joint interrogation in a single atom interferometer which overcomes the dead time between consecutive measurements in standard cold atomic fountains. The joint operation enables for a faster averaging of the Dick effect associated with the local oscillator noise in clocks and with vibration noise in cold atom inertial sensors. Such an operation allows one to achieve the lowest stability limit due to atom shot noise. We demonstrate a multiple joint operation in which up to five clouds of atoms are interrogated simultaneously in a single setup. The essential feature of multiple joint operation, demonstrated here for a microwave Ramsey interrogation, can be generalized to go beyond the current stability limit associated with dead times in present-day cold atom interferometer inertial sensors.
منابع مشابه
Cesium Atomic Fountain Clocks at Nmij
We describe the recent progress in our cesium atomic fountains at National Metrology Institute of Japan (NMIJ). We have developed three atomic fountains: NMIJ-F1, NMIJ-F2, and a truncated atomic beam fountain. NMIJ-F1 has been the primary frequency standard with uncertainty of 4×10 -15 since 2004. Especially in the last 4 years, we have reported the data to Bureau International des Poids et Mes...
متن کاملFirst results with a cold cesium continuous fountain resonator
We report on the design, construction, and preliminary measurements on the resonator of a continuous Cs fountain frequency standard. The construction of the resonator is described, preliminary measurements of the available atomic flux, and of the beam temperature are presented, along with the first Ramsey fringes (width 1 Hz) obtained in this new type of fountain. We discuss theoretical aspects...
متن کاملGROWTH OF ZnS SINGLE CRYSTALS BY CVT TECHNIQUE UNDER DIFFERENT MASS TRANSPORT STABILITY CONDITIONS
Abstract: A thermodynamic model was used to find out the optimum temperature for the growth of ZnS single crystals in closed ampoules by chemical vapor transport technique. Based on this model 1002 °C was found to be optimum temperature for 2 mg/cm3 concentration of transporting agent (iodine). ZnS Crystals were grown in optimum (1002 °C) and non-optimum (902 °C and 1102 °C) temperatures. The c...
متن کاملCold collision frequency shifts in a 87Rb atomic fountain.
We present measurements of cavity frequency pulling and collisional frequency shifts in a 87Rb fountain with a frequency resolution of 3x10(-16). Agreement with theory is found for the cavity pulling and the measured collisional shifts. The clock shift is found at least 50 times smaller than in 133Cs.
متن کاملPreliminary Results from the Usno Atomic Fountain Development Project
Atomic fountain clocks are emerging as an important new technology for the realization of extremely precise passive atomic standards. The U.S. Naval Observatory (USNO) has undertaken a project to develop atomic fountains for eventual incorporation into the USNO Master Clock. We have recently demonstrated short-term stability of ZxIO-” at I second with white frequency behavior into the mid I0,’5...
متن کامل