An Innovative Cascade System for Simultaneous Separation of Multiple Cell Types
نویسندگان
چکیده
Isolation of different cell types from one sample by fluorescence activated cell sorting is standard but expensive and time consuming. Magnetic separation is more cost effective and faster by but requires substantial effort. An innovative pluriBead-cascade cell isolation system (pluriSelect GmbH, Leipzig, Germany) simultaneously separates two or more different cell types. It is based on antibody-mediated binding of cells to beads of different size and their isolation with sieves of different mesh-size. For the first time, we validated the pluriSelect system for simultaneous separation of CD4+- and CD8+-cells from human EDTA-blood samples. Results were compared with those obtained by magnetic activated cell sorting (MACS; two steps -first isolation of CD4+, then restaining of the residual cell suspension with anti-human CD8+ MACS antibody followed by the second isolation). pluriSelect separation was done in whole blood, MACS separation on density gradient isolated mononuclear cells. Isolated and residual cells were immunophenotyped by 7-color 9-marker panel (CD3; CD16/56; CD4; CD8; CD14; CD19; CD45; HLA-DR) using flow cytometry. Cell count, purity, yield and viability (7-AAD exclusion) were determined. There were no significant differences between both systems regarding purity (MACS (median[range]: 92.4% [91.5-94.9] vs. pluriSelect 95% [94.9-96.8])) of CD4+ cells, however CD8+ isolation showed lower purity by MACS (74.8% [67.6-77.9], pluriSelect 89.9% [89.0-95.7]). Yield was not significantly different for CD4 (MACS 58.5% [54.1-67.5], pluriSelect 67.9% [56.8-69.8]) and for CD8 (MACS 57.2% [41.3-72.0], pluriSelect 67.2% [60.0-78.5]). Viability was slightly higher with MACS for CD4+ (98.4% [97.8-99.0], pluriSelect 94.1% [92.1-95.2]) and for CD8+-cells (98.8% [98.3-99.1], pluriSelect 86.7% [84.2-89.9]). pluriSelect separation was substantially faster than MACS (1h vs. 2.5h) and no pre-enrichment steps were necessary. In conclusion, pluriSelect is a fast, simple and gentle system for efficient simultaneous separation of two and more cell subpopulation directly from whole blood and provides a simple alternative to magnetic separation.
منابع مشابه
Relationship between Mitochondrial Dysfunction and Multiple Sclerosis: A Review Study
Multiple sclerosis (MS) is a chronic inflammatory demyelinating disease of the central nervous system that inflammation, demyelination, oligodendrocyte loss, gliosis, axonal injury and neurodegeneration are the main histopathological hallmarks of the disease. Although MS was classically thought as a demyelinating disease, but axonal injury occurs commonly in acute inflammatory lesions. In MS mi...
متن کاملAn innovative algorithm for planning and scheduling healthcare units with the aim of reducing the length of stay for patients (Case study: Cardiac SurgeryWard of Razavi Hospital of Mashhad)
One of the key applications of operational research in health systems management is to improve the mechanism of resource allocation and program planning in order to increase the system efficiency. This study seeks to offer an innovative method for the planning and scheduling of health service units with the aim of reducing the patients' Length of Stay (LOS) in the Cardiac Surgery Ward of Razavi...
متن کاملSimultaneous Photo-Oxidative Degradation of EDTA and Extro-Oxidative Recovery of Copper from Industrial Effluents
The objectives of this investigation are the studies on the effect of copper ion on photolytic degradation of ethylenediaminetertraaceticacid (EDTA), the effect of EDTA on electrolytic recovery of copper as well as the introduction of a novel combined photolytic and electrolytic cell system for simultaneous recovery of copper and the degradation of EDTA.In this experimental study, ...
متن کاملFuzzy PD Cascade Controller Design for Ball and Beam System Based on an Improved ARO Technique
The ball and beam system is one of the most popular laboratory setups for control education. In this paper, we design a fuzzy PD cascade controller for a ball and beam system using Asexual Reproduction Optimization (ARO) technique. The ball & beam system consists of a servo motor, a grooved beam, and a rolling ball. This system utilizes a servo motor to control ball’s position on the beam. Chan...
متن کاملمروری بر انواع آشکارسازهای اتصالی در سیستمهای کروماتوگرافی مایع برای تشخیص و اندازهگیری مواد منفجره
Abstract high-performance liquid chromatography (HPLC) are including systems used for separation of explosive mixtures that despite the advantages of rapid analysis, low sample volume, and low consumption organic solvent, in use for complex matrices need to improve the selectivity and sensitivity stationary phase. One of the methods to improve selectivity and sensitivity is choosing the appr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2013