Marked troponin elevation after implantation of a permanent antibradycardia pacemaker.

نویسندگان

  • Nikolaos I Nikolaou
  • Apostolos H Christou
  • Stavros G Spanodimos
  • Dionysios G Antonatos
  • Panagiotis I Korkonikitas
  • Sotirios P Patsilinakos
چکیده

INTRODUCTION Transvenous insertion of endocardial leads for permanent pacing is often accompanied by minor myocardial damage, detected thanks to the high sensitivity of cardiac troponins. It is unknown whether higher troponin levels, commensurate with more severe myocardial damage, can be encountered after implantation procedures. METHODS Over a 3-year period, 283 patients underwent an implantation of a full antibradycardia pacemaker system (pulse generator plus leads). Patients were required to have normal levels of cardiac troponin I (CTNI) on a venous blood sample taken immediately prior to elective pacemaker insertion. Post implantation CTNI levels were measured in all patients 6 hours after the procedure. Repeated samples were taken if high CTNI levels were found at 6 hours. RESULTS Elevated CTN-I levels were found in 167 patients (59%, 95% CI: 0.53-0.64), but only 5 of them (1.8%, 95% CI=0.8 to 4.1%) had peak CTN-I levels far exceeding the range of minimal myocardial damage (i.e. CTN-I >1.5 ng/ml). Implantation of the devices was successful in all patients and we did not observe any complications. None had clinical evidence of an acute coronary event before or during the pacemaker implantation procedure and coronary angiography revealed no significant lesions in the coronary arteries. CONCLUSIONS CTN-I elevations after pacemaker implantation may far exceed levels corresponding to minimal myocardial damage. This should be a matter of concern, especially if an early discharge is planned after pacemaker implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Periprocedural cardiac troponin elevation: a potential indicator of enhanced ventricular threshold in permanent pacemaker recipients

Background and aim: Permanent cardiac pacing is the most efficient treatment for patients with symptomatic bradycardia and high-degree atrioventricular (AV) block. For effective pacing, sensing and pacemaker battery longevity; ventricular pacing threshold (VPT) levels, lead impedance levels and Rwave amplitude levels must be desirable. We aimed to search the association between elevated serum t...

متن کامل

Adverse Interactions between ICD and Permanent Pacemaker Systems

After the introduction of the implantable cardioverter defibrillator (ICD) in clinical practice by Mirowski in 1980 [Mirowski et al., 1980] the first available devices offered only a basic ventricular pacing option. Since approximately 5-20% of patients with an indication for ICD therapy following implantation criteria at that time (secondary prevention) needed antibradycardia pacing as well, t...

متن کامل

Marked ST‐segment elevation during permanent pacemaker implantation

Some acute complications are known during permanent pacemaker implantation such as pneumothorax, lead perforation, lead dislodgement, and hemorrhage. ST-segment elevation in electrocardiogram during implantation is rare, but it might indicate critical complication like myocardial ischemia or ventricular perforation. Physicians should pay attention about ST-segment change during pacemaker implan...

متن کامل

Nothing inside the heart – Combining epicardial pacing with the S-ICD

Introduction The implantation of implantable cardioverter-defibrillator (ICD) systems in patients with no or limited venous access is technically challenging. After disappointing experiences with epicardial ICD patches, surgical techniques focused on the implantation of subcutaneous high-voltage array electrodes or intrapericardial placement of standard transvenous ICD leads. The Boston Scienti...

متن کامل

The Effect of a Self-Care Program on the Quality of Life of Patients with Permanent Pacemaker

Introduction. Today, the subject of patient education as well as education for their families is mainly about acceptance of self-care by patients. Therefore, proper conditions should be provided for patients to be able to take care of themselves. This study attempts to examine the effects of a self-care program on quality of life of patients having permanent pacemaker. Methods. A quasi-experim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese

دوره 52 6  شماره 

صفحات  -

تاریخ انتشار 2011