When minutes count--the fallacy of accurate time documentation during in-hospital resuscitation.
نویسندگان
چکیده
UNLABELLED The purpose of this study is to examine the commonly held assumption that time is measured and documented accurately during resuscitation from cardiac arrest in the hospital. METHODS A two-pronged approach was used to evaluate the accuracy of time documentation and measurement. First, two existing databases-the National Registry of Cardiopulmonary Resuscitation (NRCPR) and a 240-bed hospital's repository of cardiac arrest records-were evaluated for completeness and accuracy of documentation on resuscitation records of times required for calculating the Utstein gold-standard process intervals-recognition of pulselessness to starting cardiopulmonary resuscitation (CPR), delivery of first defibrillation shock, successful intubation, and epinephrine (adrenaline) administration. Second, nurses from a 900-bed hospital were interviewed to determine timepieces used during resuscitations, and timepieces were assessed for coherence and precision. RESULTS : From the NRCPR database that included 10,689 pulseless cardiac arrests submitted by 176 hospitals, time data for calculating the Utstein intervals were missing for 10.9% of the interventions; negative intervals were calculated for 4%. From 232 consecutive resuscitation records from the 240-bed hospital, 85 records were identified from non-monitored units with staff who provided only CPR. Defibrillation, intubation and epinephrine administration were delayed until after arrival of advanced life support (ALS) responders; unlikely intervals of 0 min from event recognition to these ALS interventions were calculated for 11.5%. Sixty-seven nurses from the 900-bed hospital were interviewed; when documenting information during resuscitations, 21 (31.3%) reported using only patient room clocks, 30 (44.8%) only their watches, and 16 (23.9%) several timepieces. In all in-patient units in the same hospital, 241 timepieces (nurses' and physicians' watches, clocks in patient rooms, defibrillator clocks, central station monitors, and nursing station clocks) were compared to atomic time. The mean absolute time difference from atomic clock was 2.83 min (S.D. +/-5.9 min), median 1.88 min, and range 52.1 min slow to 72.85 min fast. There was no difference among timepieces (P = 0.35). CONCLUSIONS Missing time data, negative calculated Utstein gold-standard process intervals, unlikely intervals of 0 min from arrest recognition to ALS interventions in units with CPR providers only, use of multiple timepieces for recording time data during the same event, and wide variation in coherence and precision of timepieces bring into question the ability to use time intervals to evaluate resuscitation practice in the hospital. Practitioners, researchers and manufacturers of resuscitation equipment must come together to create a method to collect and document accurately essential resuscitation time elements. Our ability to enhance the resuscitation process and improve patient outcomes requires that this be done.
منابع مشابه
Evaluation of effective factors in the success of resuscitation of patients with in-hospital cardiopulmonary arrest
Background: Previous studies have shown that several factors affect the outcome of cardiopulmonary resuscitation. In this study, we have evaluated the factors associated with the outcome of resuscitation in in-hospital cardiopulmonary arrest patients (IHCA) 002E. Methods: This cross-sectional non-probability study was performed on patients with in-hospital cardiopulmonary arrest between 2015 a...
متن کاملSurvival after In-Hospital Cardiopulmonary Resuscitation in a Major Referral Center during 2001-2008
Despite efforts to save more people suffering from in-hospital cardiac arrest, rates of survival after in-hospital cardiopulmonary resuscitation (CPR) are no better today than they were more than a decade ago. This study was undertaken to assess the demographics, clinical parameters and outcomes of patients undergoing CPR by the code blue team at our center during 2001 to 2008. Data were collec...
متن کاملA Study of Cerebral Performance Categories Based on Initial Rhythm and Resuscitation Time Following In-Hospital Cardiac Arrest in a State Hospital in Turkey
Background: The cerebral performance category (CPC) score is widely used in research and quality assurance to assess neurologic outcome following cardiac arrest. However, little is known about the results of the CPC in Turkey. Objective: This study aimed to determine whether the CPC is associated with the initial rhythm and resuscitation time following re...
متن کاملOutcomes of cardiopulmonary resuscitation in the emergency department
Objective: Cardiopulmonary resuscitation (CPR) is a lifesaving technique useful in the prevention of death or delaying it in a person with cardiac arrest. In this regard, demographic information about patients who need CPR is vital. Methods: In this cross-sectional study patients with cardiopulmonary arrest or arrhythmias admitted to Imam Reza and Sina ed...
متن کاملAssessment of Performance Index of Emergency Department in a Hospital in Tehran, Iran
Background: Evaluating and monitoring the performance of emergency departments (EDs) are steps in one of the most important processes to improving the efficiency of hospitals. Indicators such as patient wait time until being visited by a doctor, patient wait time from the order until admission, percentage of patients with a determined order, time of conversion of a patient’s co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Resuscitation
دوره 65 3 شماره
صفحات -
تاریخ انتشار 2005