Internal carotid artery stenosis: accuracy of subjective visual impression for evaluation with digital subtraction angiography and contrast-enhanced MR angiography.

نویسندگان

  • Jean Marie U-King-Im
  • Martin J Graves
  • Justin J Cross
  • Nicholas J Higgins
  • Josephine Wat
  • Rikin A Trivedi
  • Tjun Tang
  • Simon P S Howarth
  • Peter J Kirkpatrick
  • Nagui M Antoun
  • Jonathan H Gillard
چکیده

PURPOSE To prospectively determine, for both digital subtraction angiography (DSA) and contrast material-enhanced magnetic resonance (MR) angiography, the accuracy of subjective visual impression (SVI) in the evaluation of internal carotid artery (ICA) stenosis, with objective caliper measurements serving as the reference standard. MATERIALS AND METHODS Local ethics committee approval and written informed patient consent were obtained. A total of 142 symptomatic patients (41 women, 101 men; mean age, 70 years; age range, 44-89 years) suspected of having ICA stenosis on the basis of Doppler ultrasonographic findings underwent both DSA and contrast-enhanced MR angiography. With each modality, three independent neuroradiologists who were blinded to other test results first visually estimated and subsequently objectively measured stenoses. Diagnostic accuracy and percentage misclassification for correct categorization of 70%-99% stenosis were calculated for SVI, with objective measurements serving as the reference standard. Interobserver variability was determined with kappa statistics. RESULTS After exclusion of arteries that were unsuitable for measurement, 180 vessels remained for analysis with DSA and 159 vessels remained for analysis with contrast-enhanced MR angiography. With respect to 70%-99% stenosis, SVI was associated with average misclassification of 8.9% for DSA (8.9%, 7.8%, and 10.0% for readers A, B, and C, respectively) and of 11.7% for contrast-enhanced MR angiography (11.3%, 8.8%, and 15.1% for readers A, B, and C, respectively). Negative predictive values were excellent (92.3%-100%). Interobserver variability was higher for SVI (DSA, kappa = 0.62-0.71; contrast-enhanced MR angiography, kappa = 0.57-0.69) than for objective measurements (DSA, kappa = 0.75-0.80; contrast-enhanced MR angiography, kappa = 0.66-0.72). CONCLUSION SVI alone is not recommended for evaluation of ICA stenosis with both DSA and contrast-enhanced MR angiography. SVI may be acceptable as an initial screening tool to exclude the presence of 70%-99% stenosis, but caliper measurements are warranted to confirm the presence of such stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of contrast-enhanced MR angiography in predicting angiographic stenosis of the internal carotid artery: linear regression analysis.

BACKGROUND AND PURPOSE We sought to assess whether contrast-enhanced MR angiography is able to predict the degree of angiographic stenosis of the internal carotid artery within a clinically acceptable margin of error, thereby decreasing the need for angiography. In addition, we sought to assess whether adding ultrasound peak systolic velocity (PSV) as an additional regressor improves the accura...

متن کامل

Preoperative evaluation of carotid artery stenosis: comparison of contrast-enhanced MR angiography and duplex sonography with digital subtraction angiography.

BACKGROUND AND PURPOSE Contrast-enhanced MR angiography and extracranial color-coded duplex sonography are noninvasive, preoperative imaging modalities for evaluation of carotid artery stenosis. Innovative techniques and improvements in image quality require frequent reassessment of accuracy, reliability, and diagnostic value compared with those of digital subtraction angiography (DSA). We eval...

متن کامل

Prospective evaluation of carotid artery stenosis: elliptic centric contrast-enhanced MR angiography and spiral CT angiography compared with digital subtraction angiography.

BACKGROUND AND PURPOSE Although digital subtraction angiography (DSA) is the reference standard for assessing carotid arteries, it is uncomfortable for patients and has a small risk of disabling stroke and death. These problems have fueled the use of spiral CT angiography and MR angiography. We prospectively compared elliptic centric contrast-enhanced MR angiography and spiral CT angiography wi...

متن کامل

ارزیابی و بررسی نتایج حاصل از داپلر فراصوتی در مقایسه با آنژیوگرافی تفریقی دیجیتال در تشخیص تنگ شدگیهای شریان کاروتید داخلی

Introduction: Digital Subtraction Angiography (DSA) is the standard method for detection of carotid artery stenosis. This technique has high radiation dose. With the progress of imaging techniques, noninvasive or minimally invasive methods like the CT angiography, MR angiography and ultrasonography with Doppler or Duplex mode were applicable. This study aimed to evaluate and assesse the results...

متن کامل

Contrast-enhanced three-dimensional magnetic resonance angiography of atherosclerotic internal carotid stenosis as the noninvasive imaging modality in revascularization decision making.

BACKGROUND AND PURPOSE In patients with severe internal carotid artery stenoses, thromboendarterectomy significantly reduces both ischemic stroke and the risk of more ischemic attacks. Digital subtraction angiography (DSA) is the accepted preoperative test to determine whether a high-grade stenosis is present and requires surgical therapy. However, DSA has a procedural risk of stroke between 0....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 244 1  شماره 

صفحات  -

تاریخ انتشار 2007