Impact of Acetazolamide and CPAP on Cortical Activity in Obstructive Sleep Apnea Patients

نویسندگان

  • Katrin Stadelmann
  • Tsogyal D. Latshang
  • Yvonne Nussbaumer-Ochsner
  • Leila Tarokh
  • Silvia Ulrich
  • Malcolm Kohler
  • Konrad E. Bloch
  • Peter Achermann
چکیده

STUDY OBJECTIVES 1) To investigate the impact of acetazolamide, a drug commonly prescribed for altitude sickness, on cortical oscillations in patients with obstructive sleep apnea syndrome (OSAS). 2) To examine alterations in the sleep EEG after short-term discontinuation of continuous positive airway pressure (CPAP) therapy. DESIGN Data from two double-blind, placebo-controlled randomized cross-over design studies were analyzed. SETTING Polysomnographic recordings in sleep laboratory at 490 m and at moderate altitudes in the Swiss Alps: 1630 or 1860 m and 2590 m. PATIENTS Study 1: 39 OSAS patients. Study 2: 41 OSAS patients. INTERVENTIONS Study 1: OSAS patients withdrawn from treatment with CPAP. Study 2: OSAS patients treated with autoCPAP. Treatment with acetazolamide (500-750 mg) or placebo at moderate altitudes. MEASUREMENTS AND RESULTS An evening dose of 500 mg acetazolamide reduced slow-wave activity (SWA; approximately 10%) and increased spindle activity (approximately 10%) during non-REM sleep. In addition, alpha activity during wake after lights out was increased. An evening dose of 250 mg did not affect these cortical oscillations. Discontinuation of CPAP therapy revealed a reduction in SWA (5-10%) and increase in beta activity (approximately 25%). CONCLUSIONS The higher evening dose of 500 mg acetazolamide showed the "spectral fingerprint" of Benzodiazepines, while 250 mg acetazolamide had no impact on cortical oscillations. However, both doses had beneficial effects on oxygen saturation and sleep quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors Affecting Patients’ Adherence to Continuous Positive Airway Pressure Therapy for Obstructive Sleep Apnea Disorder: A Multi-Method Approach

Background: Continuous positive airway pressure (CPAP) is the gold standard therapy for treating obstructive sleep apnea (OSA) disorder. However, patients’ adherence to its regular use is poor. The present study aimed to determine the adherence rate to CPAP therapy by identifying factors affecting its regular use and its associated problems and discomforts among a sample population in Mashhad (...

متن کامل

Apert Syndrome with Obstructive Sleep Apnea: A Case Report

Apert syndrome is a rare kind of craniosynostosis which is identified with fusion of cranial sutures during prematurity period and causes physical and intellectual disorders in younger ages. These patients may show symptoms of obstructive sleep apnea due to abnormal craniofacial shape. This article introduces a patient with Apert syndrome, with apnea symptoms, cyanosis, snoring, restlessness, n...

متن کامل

How to treat patients with obstructive sleep apnea syndrome during an altitude sojourn.

Considering the high prevalence of the obstructive sleep apnea syndrome (OSA), it is expected that many patients with the disorder are traveling to altitude. However, this may expose them to the risk of pronounced hypoxemia, exacerbation of nocturnal breathing disturbances by frequent central apneas, impaired daytime performance, and high blood pressure. Recently, randomized studies specificall...

متن کامل

CPAP should not be used for central sleep apnea in congestive heart failure patients.

399 B oth sleep apnea and congestive heart failure are common disorders. However, systolic heart failure appears to be the most common cause of central and perhaps obstructive sleep apnea. Obstructive sleep apnea is also common in isolated diastolic heart failure and may contribute to the progression of left ventricular remodeling and perhaps play a causative role. 1,3-6 However, prevalence and...

متن کامل

بومی‌سازی راهنمای بالینی تیتراسیون دستی CPAP و BPAP در بیماران مبتلا به آپنه انسدادی خواب

Introduction: obstructive sleep apnea is a common disease that is recognized as the leading cause of occupational injuries and accidents. Proper assessment and treatment of employees affected by this disease can reduce the numerous side effects if the methods used to identify and treat these patients are evidence based and are applicable in our country. Methods: In order to standardize the c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014