Blood Pressure Cuff as a Potential Vector of Pathogenic Microorganisms: A Prospective Study in a Teaching Hospital
نویسنده
چکیده
results. A level of contamination reaching 100 or more colony-forming units per 25 cm was observed on 92 (45%) of inner sides and 46 (23%) of outer sides of 203 cuffs. The highest rates of contamination occurred on the inner side of BP cuffs kept in intensive care units (ICUs) (20 [83%] of 24) or on nurses’ trolleys (27 [77%] of 35). None of the 18 BP cuffs presumed to be clean (ie, those that had not been used since the last decontamination procedure) had a high level of contamination. Potentially pathogenic microorganisms were isolated from 27 (13%) of the 203 BP cuffs: 20 of these microorganisms were Staphylococcus aureus, including 9 methicillin-resistant strains. The highest rates of contamination with potentially pathogenic microorganisms were observed on cuffs used in ICUs and those kept on nurses’ trolleys. For 4 patients with a personal sphygmomanometer, a genetic link was found between the strains isolated from the BP cuffs and the strains isolated from the patients.
منابع مشابه
Blood pressure cuff as a potential vector of pathogenic microorganisms: a prospective study in a teaching hospital.
OBJECTIVE To investigate the potential role of blood pressure (BP) cuffs in the spread of bacterial infections in hospitals. DESIGN A comprehensive, prospective study quantitatively and qualitatively evaluating the bacterial contamination on BP cuffs of 203 sphygmomanometers in use in 18 hospital units from January through March 2003. SETTING A university hospital with surgical, medical, an...
متن کاملTHE EFFECT OF CHANGE IN POSITION ON INTRATRACHEAL CUFF PRESSURE IN PATIENTS UNDERGOING SURGERY WITH GENERAL ANESTHESIA: A PROSPECTIVE ANALYTICAL STUDY
Background & Aims: Tracheal intubation with a cuffed tube for the administration of general anesthesia is routine. The cuff of the endotracheal tube is inflated with air to achieve an adequate seal to prevent aspiration and leakage of air and anesthetic gases. Whereas over-inflation can decrease the mucosal perfusion, leading to pressure necrosis and nerve palsies. This study aimed to evaluate ...
متن کاملComparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study
Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...
متن کاملتخمین بدون کاف فشارخون مبتنی بر ویژگیهای زمانی سیگنال نبض
Blood pressure is one of the vital signs. Specially, it is crucial for some cases such as hypertension patients and it should be monitored continuously in ICU/CCU. It must be noted that current systems to measure blood pressure, often require trained operators. As an example, in post-hospital cares, blood pressure control is difficult except with the presence of a nurse or use of a device that ...
متن کاملDesigning and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals
Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -