Prediction of hemodialysis sorbent cartridge urea nitrogen capacity and sodium release from in vitro tests.

نویسندگان

  • Benjamin P Rosenbaum
  • Stephen R Ash
  • Raymond J Wong
  • R Preston Thompson
  • David J Carr
چکیده

In sorbent-based hemodialysis, factors limiting a treatment session are urea conversion capacity and sodium release from the cartridge. In vitro experiments were performed to model typical treatment scenarios using various dialyzers and 4 types of SORB sorbent cartridges. The experiments were continued to the point of column saturation with ammonium. The urea nitrogen removed and amount of sodium released in each trial were analyzed in a multi-variable regression against several variables: amount of zirconium phosphate (ZrP), dialysate flow rate (DFR), simulated blood flow rate (BFR), simulated patient whole-body fluid volume (V), initial simulated patient urea concentration (BUNi), dialyzer area permeability (KoA) product, initial dialysate sodium and bicarbonate (HCO3i) concentrations, initial simulated patient sodium (Nai), pH of ZrP, creatinine, breakthrough time, and average urea nitrogen concentration in dialysate. The urea nitrogen capacity (UNC) of various new SORB columns is positively related to ZrP, BFR, V, BUNi, and ZrP pH and negatively to DFR with an R2 adjusted=0.990. Two models are described for sodium release. The first model is related positively to DFR and V and negatively to ZrP, KoA product, and dialysate HCO3i with an R2 adjusted=0.584. The second model incorporates knowledge of initial simulated patient sodium (negative relationship) and urea levels (negative relationship) in addition to the parameters in the first model with an R2 adjusted=0.786. These mathematical models should allow for prediction of patient sodium profiles and the time of column urea saturation based on simple inputs relating to patient chemistries and the dialysis treatment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the effect of exercise on serum creatinine and urea nitrogen in hemodialysis patients

Introduction. Chronic renal failure is a progressive disease in which kidney function is impaired, so that the body can not metabolize and maintain fluid balance and electrolytes. Therefore, the present study investigated changes in serum creatinine and urea nitrogen in hemodialysis patients in response to exercise. Materials and Methods. The subjects of this study were dialysis patients who we...

متن کامل

Robust, reliable biosensor for continuous monitoring of urea during dialysis.

We developed a new urea sensor for the on-line monitoring of hemodialysis adequacy. The biosensor consisted of an immobilized urease cartridge placed between magnetoinductive conductivity cells. The biosensor output was taken as the conductivity difference between these cells. The device was placed on the ultrafiltrate line of a paired filtration dialysis system. The amount of urease present in...

متن کامل

In Vitro Release Studies of Enoxaparin in Nanoparticle form and Enterically Coated Tablets Containing Surfactants

In the past decade, many strategies have been developed to enhance oral drug delivery. Different techniques were investigated, amongst those the use of permeation enhancers such surfactants and biodegradable polymers were studied more extensively. Chitosan and its derivatives have been studied as permeation enhancer. The aim of the current study was to develop a nanoparticulate system based on ...

متن کامل

The Evaluation of Dietary Protein Intake by Calculation of Urea Generation Rate in Chronic Dialysis Patients in Kerman, 2002

Malnutrition is a common problem in chronic dialysis patients. There are several methods for nutritional assessment of hemodialysis patients, such as calculation of urea generation rate. As urea is produced from proteins catabolism and there is a linear correlation between urea generation and protein catabolic rate (PCR), PCR can be calculated by considering urea nitrogen appearence during the ...

متن کامل

A Proposed Peritoneal-Based Wearable Artificial Kidney.

Ideally, an artificial kidney should simulate the normal kidney in providing continuous metabolic control, removal of toxins, and unrestricted patient freedom. Of the dialysis procedures available, continuous ambulatory peritoneal dialysis (CAPD) comes the closest to this ideal but provides inadequate dialysis and fails to remove protein-bound toxins. A continuous, wearable, peritoneal-based ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Hemodialysis international. International Symposium on Home Hemodialysis

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 2008