Intrafractional baseline drift during free breathing breast cancer radiation therapy.

نویسندگان

  • Christer Andre Jensen
  • Ana María Acosta Roa
  • Jo-Åsmund Lund
  • Jomar Frengen
چکیده

BACKGROUND Intrafraction motion in breast cancer radiation therapy (BCRT) has not yet been thoroughly described in the literature. It has been observed that baseline drift occurs as part of the intrafraction motion. This study aims to measure baseline drift and its incidence in free-breathing BCRT patients using an in-house developed laser system for tracking the position of the sternum. MATERIALS AND METHODS Baseline drift was monitored in 20 right-sided breast cancer patients receiving free breathing 3D-conformal RT by using an in-house developed laser system which measures one-dimensional distance in the AP direction. A total of 357 patient respiratory traces from treatment sessions were logged and analysed. Baseline drift was compared to patient positioning error measured from in-field portal imaging. RESULTS The mean overall baseline drift at end of treatment sessions was -1.3 mm for the patient population. Relatively small baseline drift was observed during the first fraction; however it was clearly detected already at the second fraction. Over 90% of the baseline drift occurs during the first 3 min of each treatment session. The baseline drift rate for the population was -0.5 ± 0.2 mm/min in the posterior direction the first minute after localization. Only 4% of the treatment sessions had a 5 mm or larger baseline drift at 5 min, all towards the posterior direction. Mean baseline drift in the posterior direction in free breathing BCRT was observed in 18 of 20 patients over all treatment sessions. CONCLUSIONS This study shows that there is a substantial baseline drift in free breathing BCRT patients. No clear baseline drift was observed during the first treatment session; however, baseline drift was markedly present at the rest of the sessions. Intrafraction motion due to baseline drift should be accounted for in margin calculations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiration induced heart motion and indications of gated delivery for left-sided breast irradiation.

PURPOSE To investigate respiration-induced heart motion for left-sided breast irradiation using a four-dimensional computed tomography (4DCT) technique and to determine novel indications to assess heart motion and identify breast patients who may benefit from a gated treatment. METHODS AND MATERIALS Images of 4DCT acquired during free breathing for 20 left-sided breast cancer patients, who un...

متن کامل

Intrafractional dose variation and beam configuration in carbon ion radiotherapy for esophageal cancer

BACKGROUND In carbon ion radiotherapy (CIR) for esophageal cancer, organ and target motion is a major challenge for treatment planning due to potential range deviations. This study intends to analyze the impact of intrafractional variations on dosimetric parameters and to identify favourable settings for robust treatment plans. METHODS We contoured esophageal boost volumes in different organ ...

متن کامل

Quantifying variability of intrafractional target motion in stereotactic body radiotherapy for lung cancers

In lung stereotactic body radiotherapy (SBRT), variability of intrafractional target motion can negate the potential benefits of four-dimensional (4D) treatment planning that aims to account for the dosimetric impacts of organ motion. This study used tumor motion data obtained from CyberKnife SBRT treatments to quantify the reproducibility of probability motion function (pmf) of 37 lung tumors....

متن کامل

Dosimetric effects of intrafractional isocenter variation during deep inspiration breath‐hold for breast cancer patients using surface‐guided radiotherapy

The aim of this study was to investigate potential dose reductions to the heart, left anterior descending coronary artery (LAD), and ipsilateral lung for left-sided breast cancer using visually guided deep inspiration breath-hold (DIBH) with the optical surface scanning system Catalyst™, and how these potential dosimetric benefits are affected by intrafractional motion in between breath holds. ...

متن کامل

Inter‐ and intrafractional setup errors and baseline shifts of fiducial markers in patients with liver tumors receiving free‐breathing postoperative radiation analyzed by cone‐beam computed tomography

This study was to evaluate the interfractional and intrafractional setup errors and baseline shifts of golden fiducial markers in patients receiving postoperative radio- therapy (RT) using cone-beam computed tomography (CBCT) in order to calculate PTV margins for patients with liver cancer. Twelve patients with liver tumors under- went postoperative RT. CBCT images were acquired before and afte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta oncologica

دوره 56 6  شماره 

صفحات  -

تاریخ انتشار 2017