Attenuation effects on imaging diagnostics of hollow-cone sprays.

نویسندگان

  • V Sick
  • B Stojkovic
چکیده

Detrimental effects to quantitative interpretation of Mie and laser-induced fluorescence images of hollow-cone sprays were investigated. The attenuation of the laser beam leads to locally unknown intensities rendering it impossible to obtain high-fidelity images of these sprays. Two strategies that use bidirectional illumination of the spray are discussed and evaluated. Conditions for which a bidirectional illumination, single-image detection will allow good recovery of the spray structure are identified. Furthermore, the attenuation of laser-induced fluorescence signals on their path through the spray is quantified.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of structured illumination for multiple scattering suppression in planar laser imaging of dense sprays.

A novel approach to reduce the multiple light scattering contribution in planar laser images of atomizing sprays is reported. This new technique, named Structured Laser Illumination Planar Imaging (SLIPI), has been demonstrated in the dense region of a hollow-cone water spray generated in ambient air at 50 bars injection pressure. The idea is based on using an incident laser sheet which is spat...

متن کامل

An Experimental formulation for PFI injector penetration length versus time and pressure using high speed spray imaging results

Recently, there have been problems with particulate matter pollution in diesel engines and it has reduced production rate of these engines and also, it has accelerated the development of new technologies for PFI and GDI gasoline engines. The spray characteristics has significant impact on the combustion efficiency, power and emissions on internal combustion engines. In This study, effect of inj...

متن کامل

New model for light propagation in highly inhomogeneous polydisperse turbid media with applications in spray diagnostics.

Modern optical diagnostics for quantitative characterization of polydisperse sprays and other aerosols which contain a wide range of droplet size encounter difficulties in the dense regions due to the multiple scattering of laser radiation with the surrounding droplets. The accuracy and efficiency of optical measurements can only be improved if the radiative transfer within such polydisperse tu...

متن کامل

Evaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners

Introduction: Cone-beam CT (CBCT) is an imaging system which offers three-dimensional (3D), multiplanar images and has many advantages over computed tomography (CT) including shorter acquisition times for the resolution desired in dentistry, lower radiation dose to the patient, reasonable price and higher spatial resolution but CBCT scanners are unable to display actual Hounsf...

متن کامل

Experimental Investigation of Impinging Diesel Sprays for HCCI Combustion

............................................................................................................. I ACKNOWLEDGEMENTS .................................................................................... II LIST OF PAPERS................................................................................................. III BACKGROUND.........................................................

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 40 15  شماره 

صفحات  -

تاریخ انتشار 2001