Standardization of prostate-specific antigen (PSA) assays: can interchangeability of PSA measurements be improved?

نویسنده

  • Midori Ishibashi
چکیده

The landscape of prostate cancer has changed since the appearance of the first prostate-specific antigen (PSA) assay. PSA testing has gained rapid recognition since M. Kuriyama et al. (1 ) of Roswell Park first reported clinical studies using an enzyme immunoassay with anti-PSA rabbit antibody. Mikolajczyk and coworkers (2, 3) reported the presence of several free PSA isoforms and the potential application of free PSA isoforms as serum markers. Today, more than 30 types of total PSA assay reagent sets and 10 types of free PSA and PSA– 1-antichymotrypsin (ACT) assays, based on various principles, are available. Key elements in PSA measurement are interchangeability of assays and stability of serum samples before tests (4, 5). Efforts to standardize PSA assays were initiated in 1992 at the First Stanford Conference, organized by T. Stamey. At the Second Stanford Conference on International Standardization of Prostate-Specific Antigen (1994), Stamey et al. (6 ) proposed a primary calibrator consisting of 90% purified PSA-ACT and 10% free PSA (90:10) on a molar basis. Subsequently, the Clinical and Laboratory Standards Institute (CLSI; formerly NCCLS) issued a document (7 ) recommending a set of 3 distinct materials containing 100% free PSA, 100% PSA-ACT, and 90% PSA-ACT:10% free PSA. This document led to further activity in the harmonization of PSA assays. In 1999, Robert M. Nakamura, a member of the International Consultation Committee on Prostate Cancer, made recommendations, with his colleagues (8 ), on standardization and quality assessment of PSA immunoassays. The recommendations included the following: (a) free PSA should be the primary standard for free PSA and total PSA immunoassays; (b) assays should exhibit an equimolar response to free PSA and PSA-ACT complexes; (c) assay antibodies to free PSA should not cross-react with human kallikrein 2 (hK2); (d) reference values for free PSA/total PSA need to be established for each assay combination; and (e) clinical laboratories should specify the name of the assay on their reports. Kuriyama et al. (9 ) studied 9 commercially available assays for total PSA and described equations to calculate the expected Tandem-R PSA (Beckman Coulter) results from the PSA concentrations obtained with the other methods studied. That report has been widely used in clinical studies. At the time of the report by Kuriyama et al., however, the concept of equimolarity of assays was not well established, and the risk of converting results among assays, without knowing the reactivities of the antibodies in the different reagent sets, was not assessed. The heterogeneity of PSA forms in serum was later described in detail (10 ), and the effect of that heterogeneity on results of immunoassays became fully appreciated. In 1997, the Committee of Investigation on PSA Assay (sponsored by the Japanese Urological Association and the Japanese Society of Laboratory Medicine) carried out a survey of the variability among assays. Patient serum, purified 100% free PSA, and purified 100% PSA-ACT were prepared for survey samples. We studied 28 total PSA assays from 22 manufacturers and analyzed the reactivity ratios of free PSA to PSA-ACT in those assays by dilution tests using purified 100% free PSA and purified 100% PSA-ACT. The study revealed that the differences among measurement schemes were related to differences in the reactivities of antibodies for free PSA and PSA-ACT caused by the variety of PSA molecular forms. In 2000, we performed another survey focusing on the clinically important total PSA range up to 20 g/L (11 ). In that survey, 26 assays from 18 companies were investigated. During the 3 years between our surveys, the reactivities of most assays for total PSA had been improved. In the initial survey, only 34% of the assays showed an equimolar response to free PSA and PSA-ACT. The minimum and maximum measured values were 4.1 and 32.3 g/L for the serum sample containing 40% free PSA (11 ). Large disparities persist among assays, however. We attribute this variability, in part, to matrix differences between serum samples and the WHO buffer-based reference material used for assignment of values to the assay calibrators. Anti-PSA antibodies show different reactivities and affinities for the various forms of free PSA and PSA-ACT in bufferor serum-based samples. The goal of PSA standardization efforts is to improve harmonization of results for patient serum samples, but the WHO primary standard materials use buffer with added bovine serum albumin, and assay calibrators use various matrices. Ideally, the total PSA assay should have an equimolar response for free PSA and PSA-ACT. We examined the matrix effect among the bufferand serum-based samples by measuring purified free PSA and PSA-ACT. The differences in the measured concentrations for buffer-based vs serum-based samples reported by the AxSYM (Abbott Diagnostics) and ADVIA Centaur (Bayer) were 4%, in contrast to those reported by the Elecsys (Roche Diagnostics), Access (Beckman Coulter), and Immulite (Diagnostic Products Corp.), which were 9%, 7%, and 18%, respectively. In all cases, PSA-ACT showed greater reactivity than did free PSA. The standardization of PSA assays is limited because only primary reference materials (WHO reference materials) have been prepared and because PSA does not have a total reference measurement system including reference materials and a reference measurement procedure. To further promote standardization, a reference measurement system should be established to transmit the accuracy of the buffer-based primary standard material to patient serum, which is the final goal. In a comprehensive study in this issue of Clinical Chemistry, Stephan et al. (12 ) show that interchangeability Editorials

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interchangeability of measurements of total and free prostate-specific antigen in serum with 5 frequently used assay combinations: an update.

BACKGROUND The comparability of total and free prostate-specific antigen (tPSA and fPSA) results among commercial PSA assays has been suggested to be improved by calibration to WHO PSA reference materials and the development of equimolar-response assays. To characterize the current situation, we assessed 5 frequently used commercial assay combinations for tPSA and fPSA regarding the interchange...

متن کامل

Age Specific Reference Levels of Serum Prostate-Specific Antigen, Prostate Volume and Prostate Specific Antigen Density in Healthy Iranian Men

Background: It is relevant to highlight that there is not a precise and perfect report on either 95 percentile value (upper limit of normal range) or on appropriate reference intervals for serum PSA in Iranian population. Objective: To determine age-specific reference ranges for serum prostate-specific antigen (PSA) concentration and PSA density (PSAD) and prostate volumes in a population of he...

متن کامل

What is the most appropriate test in detecting prostate cancer in patients with intermediate prostate specific antigen levels?

  Abstract   Background: Regarding the variety of tests present for detecting and also screening   prostate cancer and also bearing in mind the advantages and disadvantages of   these tests we decided to re-evaluate these tests (total prostate specific antigen and all   of its modifications) in detecting prostate cancer in men with intermediate serum   PSAlevels.   Methods: Following a cross se...

متن کامل

Preparation of an artificial matrix to replace human standards of prostate specific antigen IRMA assay kit [Persian]

  Introduction: Prostate specific antigen (PSA) is one of the most sensitive markers for diagnosis of prostate cancer. Immunoradiometric kit (IRMA) is a common and sensitive method for determination of PSA in clinical laboratories. This kit has four major components: solid phase coated with monocolonal antibody, pair antibody labelled with I-125, series of standards i...

متن کامل

Can Prostate Specific Antigen Be Used as New Biomarker for Early Diagnosis of Breast Cancer?

Introduction: As a glycoprotein, Plasma Prostate-Specific Antigen (PSA) is mainly produced by prostate epithelial cells and is used as a major diagnostic tool for prostate cancer. A group of researchers relate the elevated number of estrogen receptors in breast cancer samples to the over-production of PSA in this type of cancer. Therefore, the present study aimed to determine the participants' ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 52 1  شماره 

صفحات  -

تاریخ انتشار 2006