Neutron Technologies ( Paper Ii )

نویسنده

  • David A. Sparrow
چکیده

Neutrons pass relatively easily through matter and have been used successfully to interrogate the earth for bulk presence of elements, most notably those indicating petroleum. Applying these technologies to explosive detection is challenging because the “bulk” one is looking for can be as small as 100 g or less. The signals from 100 g of material are dwarfed by the background from the rest of the nearby earth and even by cosmic rays. To date, performance at confirming the presence of small amounts of ordnance is poor, even with dwells as long as 10 minutes over areas smaller than a half square meter. This is in part because of variations in the background signal over short distances on the earth’s surface, which can either mask or mimic the ordnance signal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی امکان استفاده از چشمه های نوترونی رادیوایزوتوپی در نوترون درمانی با بور

  Background : Performing successful BNCT experiments needs a suitable neutron source. Important factors of the neutron beam are flux and energy that are very important in the selection of neutron source. In most centers that use this method for treatment, reactor is a neutron source, which according to characteristics of the reactor appropriated neutrons are very high. High cost of constructin...

متن کامل

Reporting detection efficiency for semiconductor neutron detectors: A need for a standard

In the past few years, there has been an increased interest in the development of alternative neutron detection technologies. Included among many promising alternative neutron detection technologies are semiconductor-based neutron detectors. These detectors are typically small and compact, hence those methods used to characterize large gas-filled neutron detectors are inappropriate. Proposed ar...

متن کامل

Dosimetry Impact of Boron and Its Carriers Structure at Boron Neutron Capture Therapy of a Brain Tumor; A Sim- ulation Study

Introduction: Boron neutron capture therapy (BNCT) is a method of cancer treatment and potentially, two borono-L-phenylalanine (BPA) and sodium borocaptate (BSH) are used in BNCT as common boron carriers. Some previous studies have shown that the dose rate is directly related to boron concentration in the tissue. This study aimed to simulate the structure of boron carriers and brain tumor compo...

متن کامل

Dosimetry Impact of Boron and Its Carriers Structure at Boron Neutron Capture Therapy of a Brain Tumor; A Sim- ulation Study

Introduction: Boron neutron capture therapy (BNCT) is a method of cancer treatment and potentially, two borono-L-phenylalanine (BPA) and sodium borocaptate (BSH) are used in BNCT as common boron carriers. Some previous studies have shown that the dose rate is directly related to boron concentration in the tissue. This study aimed to simulate the structure of boron carriers and brain tumor compo...

متن کامل

Modeling a TRIGA Mark II Biological Shield using MCNP5

The 250kW TRIGA Mark II research reactor, Vienna, is equipped with experimental facilities inside and outside the reactor core. Outside the core, there are four beam tubes (three radial and one tangential beam tube), a thermal column and a neutron radiography collimator, supplying neutrons for irradiation experiments. These experiments include neutron radiography, neutron tomography, neutron ac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003