Positive serum tests for infectious mononucleosis (IM) unaccompanied by the clinical syndrome or blood changes characteristic of the disease were detected in 39/177 (22%) mentally subnormal patients investigated with three different commercially available IM slide tests. Slide positively was still detectable six months later in 27/35 (77%) positive reactors. Positive IM slide tests were significantly associated with anticonvulsant, primarily phenobarbitone therapy and with concomitant elevations of immunoglobulins IgG and IgM. Epstein Barr virus antibodies were not detectable in the sera of 8/38 (21%) positive slide reactors. The implications of these observations are discussed and attention is drawn to the variations in sensitivity, specificity, and comparability of different IM slide tests.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of the Monospot with the Paul-Bunnell test in infectious mononucleosis and other diseases.

The Monospot is a spot test designed for the diagnosis of infectious mononucleosis and its efficacy has been compared with that of the standard Paul-Bunnell test. Three out of 210 (1.4%) sera from normal persons and persons suffering from diseases other than infectious mononucleosis gave ;false' positive results when compared with the Paul-Bunnell test. Using 38 sera from patients with strong c...

متن کامل

Comparative evaluation of nine kits for rapid diagnosis of infectious mononucleosis and Epstein-Barr virus-specific serology.

Rapid diagnosis of Epstein-Barr virus (EBV)-associated infectious mononucleosis was compared by using nine kits and EBV-specific serology. Specific antibodies indicative of primary EBV infection were detected in 46 of 108 (43%) serum samples of infectious mononucleosis patients. The sensitivities and specificities of the rapid kits varied from 63 to 84% and 84 to 100%, respectively.

متن کامل

An evaluation of the Monosticon rapid slide test diagnosis of infectious mononucleosis.

A new rapid slide test for the detection of infectious mononucleosis heterophile antibody has been compared with the Paul-Bunnell absorption test. Out of 200 sera, 46 were seropositive for infectious mononucleosis by the Paul-Bunnell test and 43 of these were detected by the Monosticon test; the three Monosticon-negative sera were of low titre. There was no problem with false positive reactions...

متن کامل

Investigation of ELISA and PCR for Diagnosis of Infectious Mononucleosis

Background and Aims: Infectious mononucleosis (IM)is the clinical manifestation of primary infection with Epstein-Barr virus (EBV). Humans are the only known reservoir of EBV. Regarding the problems in diagnosis of the disease, the purpose of this study was to assess Enzyme-linked immunosorbent assay (ELISA) and Nested polymerase chain reaction (PCR) as a diagnostic tool for this disease. Mate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 28 10  شماره 

صفحات  -

تاریخ انتشار 1975