Baillie L A. Determination of liquid scintillation counting efficiency by pulse height shift. Int. J. Appl. Radiat. Isotopes 8:1-7, 1960

نویسنده

  • L A Baillie
چکیده

“The work described in this paper was inspired by the practical need to measure C14 concentrations in a large number of liquid chromatography cuts. These cuts varied in character, with some containing only clear hydrocarbons, while others contained alcohol and/or colored compounds. Counting efficiency differed for each sample, and the necessary measurement of counting efficiency by the internal standard method was tedious and time consuming. “The same mechanisms which diminish counting efficiency also diminish the light output of the scintillator vial. These include dilution, chemical quenching, and adsorption of light by color. As a result, the ratio of strong pulses to total pulses changes in a way that is related to counting efficiency. It occurred to me that a two channel spectrometer might furnish enough information so that count rate and counting efficiency might be determined simultaneously. “In order to obtain data for the calibration curves, I made up a sizable number of quenched standard vials, using various amounts of diluents, chemical quenchers, and colored material. When the ratio of strong pulses to total pulses was plotted against efficiency, I was pleased to find that most of the samples fell on the same curve. Only the strongly quenched, colored samples fell on a curve of their own. By using these curves, I was able to improve both speed and accuracy in the radioassay of my chromatography cuts. “When I decided to write a paper describing this method, it seemed appropriate to include a discussion of the effect of counting statistics on the calculated disintegration rate. This proved to be quite an interesting problem, because the same random counting errors which affect the ratio used to find the efficiency exist in the count rate itself. It develops that a random error in the group of strong pulses has some tendency to cancel out in the final answer, while a random error in the weaker group of pulses is amplified somewhat. Of course, statistical error in count rate divided by efficiency is always greater than statistical error in count rate alone. In the final analysis, the channel ratio method leads to smaller errors in routine counting than can be achieved by most alternative methods. “This paper attracted a surprising amount of attention when published in the International Journal of Applied Radiation and Isotopes. Apparently, any method which offers a reduction in tedious labor at no expense in data quality will tend to be popular among scientists.” CC/NUMBER 47 NOVEMBER 19, 1979 This Week’s Citation Classic

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photodisintegration cross section of beryllium near threshold

9 The cross section for photoneutron production in Be at energies of 1. 692, 1. 720, and 1. 78 Mev has been investigated using radioisotope gamma-ray sources. Neutron counting was by manganous sulfate bath and a long counter. Gamma-ray counting was by a scintillation spectrometer consisting of a Nal(Tl) scintillation crystal and a 256-channel pulse^height analyzer. The following results were ob...

متن کامل

Optimization Method to Determine Gross Alpha-Beta in Water Samples Using Liquid Scintillation Counter

Liquid scintillation counting (LSC) is an adequate nuclear technique to determine radioactivity levels, as verified by this study for the determination of the gross alpha and beta activities of aqueous samples because of its simplicity and low associated cost comparison with other techniques. This paper discusses a new approach to the monitoring of gross alpha and gross beta activities in water...

متن کامل

Development of a low background liquid scintillation counter for a shallow underground laboratory.

Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of low-concentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintill...

متن کامل

QUENCH: A software package for the determination of quenching curves in Liquid Scintillation counting.

In Liquid Scintillation Counting (LSC), the scintillating source is part of the measurement system and its detection efficiency varies with the scintillator used, the vial and the volume and the chemistry of the sample. The detection efficiency is generally determined using a quenching curve, describing, for a specific radionuclide, the relationship between a quenching index given by the counte...

متن کامل

Simultaneous measurement of 89Sr and 90Sr in aqueous samples by liquid scintillation counting using the spectrum unfolding method.

Two radiostrontium isotopes, 89Sr and 90Sr, were measured simultaneously by liquid scintillation counter coupling with a full spectrum DPM counting protocol. Strontium was separated from the aqueous media by extraction chromatography using Sr-spec resin. Individual count rates were evaluated from quench correlation curves for 89Sr and 90Sr related with SIS and tSIE quench indicators. The method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004