High-energy-resolution monochromator for aberration-corrected scanning transmission electron microscopy/electron energy-loss spectroscopy.
نویسندگان
چکیده
An all-magnetic monochromator/spectrometer system for sub-30 meV energy-resolution electron energy-loss spectroscopy in the scanning transmission electron microscope is described. It will link the energy being selected by the monochromator to the energy being analysed by the spectrometer, without resorting to decelerating the electron beam. This will allow it to attain spectral energy stability comparable to systems using monochromators and spectrometers that are raised to near the high voltage of the instrument. It will also be able to correct the chromatic aberration of the probe-forming column. It should be able to provide variable energy resolution down to approximately 10 meV and spatial resolution less than 1 A.
منابع مشابه
Monochromator for Aberration-Corrected STEM
In a scanning transmission electron microscope (STEM), the elemental analysis at atomic resolution is realized by the combination with electron energy-loss spectroscopy (EELS), since an aberration corrected probe forming lens system enables us to obtain an electron probe sized about 0.1 nm [1]. In EELS, the energy resolution is mainly limited by the energy spread of the electron source, which i...
متن کاملMonochromated STEM with a 30 meV-wide, atom-sized electron probe.
The origins and the recent accomplishments of aberration correction in scanning transmission electron microscopy (STEM) are reviewed. It is remembered that the successful correction of imaging aberrations of round lenses owes much to the successful correction of spectrum aberrations achieved in electron energy loss spectrometers 2-3 decades earlier. Two noteworthy examples of the types of STEM ...
متن کاملEmergent chemical mapping at atomic-column resolution by energy-dispersive x-ray spectroscopy in an aberration-corrected electron microscope.
Chemical mapping at atomic-column resolution by energy-dispersive x-ray spectroscopy in a spherical aberration-corrected scanning transmission electron microscope (STEM) has been demonstrated for the 1.47-A dumbbell structure in InGaAs. The structural imaging and the chemical information in the two-dimensional map are directly correlated. Comparisons with the other existing mapping techniques o...
متن کاملOptimum HRTEM image contrast at 20 kV and 80 kV--exemplified by graphene.
The dependence of high-resolution transmission electron microscopy (HRTEM) image contrast of graphene on the adjustable parameters of an aberration-corrected microscope operated at 80 and 20 kV has been calculated and, for 80 kV, compared with measurements. We used density functional theory to determine the projected atom potential and obtained the image intensity by averaging over the energy d...
متن کاملChanneling of Aberration-corrected STEM Probes at the “ Sub-atomic” Scale
The phenomenon of fast electron channeling in atomic crystals has long been appreciated as an important factor in TEM characterization, being particularly critical for consideration in scanning transmission electron microscopy (STEM). As such, electron channeling effects have been examined to understand the thickness-dependence of annular-dark-field (ADF) STEM image contrast [1], the emergence ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Philosophical transactions. Series A, Mathematical, physical, and engineering sciences
دوره 367 1903 شماره
صفحات -
تاریخ انتشار 2009