Anomalous transverse relaxation in 1H spectroscopy in human brain at 4 Tesla.

نویسندگان

  • S Posse
  • C A Cuenod
  • R Risinger
  • D Le Bihan
  • R S Balaban
چکیده

Longitudinal (T1) and apparent transverse relaxation times (T2) of choline-containing compounds (Cho), creatine/phosphocreatine (Cr/PCr), and N-acetyl aspartate (NAA) were measured in vivo in human brain at 4 Tesla. Measurements were performed using a water suppressed stimulated echo pulse sequence with complete outside volume presaturation to improve volume localization at short echo times. T1-values of Cho (1.2 +/- 0.1 s), Cr (1.6 +/- 0.3 s), and NAA (1.6 +/- 0.2 s) at 4 Tesla in occipital brain were only slightly larger than those reported in the literature at 1.5 Tesla. Thus, TR will not adversely affect the expected enhancement of signal-to-noise at 4 Tesla. Surprisingly, apparent T2-values of Cho (142 +/- 34 ms), Cr (140 +/- 13 ms), and NAA (185 +/- 24 ms) at 4 Tesla were significantly smaller than those at 1.5 Tesla and further decreased when increasing the mixing interval TM. Potential contributing factors, such as diffusion in local susceptibility related gradients, dipolar relaxation due to intracellular paramagnetic substances and motion effects are discussed. The results suggest that short echo time spectroscopy is advantageous to maintain signal to noise at 4 Tesla.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction: Faster Metabolite 1H Transverse Relaxation in the Elder Human Brain

(1)H magnetic resonance spectroscopy (MRS) is unique among imaging modalities because signals from several metabolites are measured during a single examination period. Each metabolite reflects a distinct intracellular process. Furthermore transverse (T2 ) relaxation times probe the viability of the cell microenvironment, e.g., the viscosity of the cellular fluids, the microscopic susceptibility...

متن کامل

1H metabolite relaxation times at 3.0 tesla: Measurements of T1 and T2 values in normal brain and determination of regional differences in transverse relaxation.

PURPOSE To measure 1H relaxation times of cerebral metabolites at 3 T and to investigate regional variations within the brain. MATERIALS AND METHODS Investigations were performed on a 3.0-T clinical whole-body magnetic resonance (MR) system. T2 relaxation times of N-acetyl aspartate (NAA), total creatine (tCr), and choline compounds (Cho) were measured in six brain regions of 42 healthy subje...

متن کامل

Ethanol in human brain by magnetic resonance spectroscopy: correlation with blood and breath levels, relaxation, and magnetization transfer.

BACKGROUND Proton magnetic resonance spectroscopy (1H MRS) allows measurement of alcohol in the human brain after alcohol consumption. However, the quantity of alcohol that can be detected in the brain by 1H MRS pulse sequences has been controversial, with values ranging from about 24% to 94% of the temporally concordant blood alcohol concentrations. The quantitation of brain alcohol is critica...

متن کامل

Investigating brain metabolism at high fields using localized 13C NMR spectroscopy without 1H decoupling.

Most in vivo 13C NMR spectroscopy studies in the brain have been performed using 1H decoupling during acquisition. Decoupling imposes significant constraints on the experimental setup (particularly for human studies at high magnetic field) in order to stay within safety limits for power deposition. We show here that incorporation of the 13C label from 13C-labeled glucose into brain amino acids ...

متن کامل

In vivo measurement of T2 relaxation times in mouse brain at 17.6 Tesla

Introduction: Transverse (T2) proton (H) magnetic resonance (MR) relaxation time plays an important role in clinics since it has a potential to distinguish different tissue types such as healthy tissue from pathological tissue [1, 2, 3]. Mice are routinely used as models for studying human brain disorders and the present trend in in vivo mouse brain MRI is to move toward ultra-high magnetic fie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 33 2  شماره 

صفحات  -

تاریخ انتشار 1995