Optimization of Anodized-Aluminum Pressure-Sensitive Paint by Controlling Luminophore Concentration

نویسندگان

  • Hirotaka Sakaue
  • Keiko Ishii
چکیده

Anodized-aluminum pressure-sensitive paint (AA-PSP) has been used as a global pressure sensor for unsteady flow measurements. We use a dipping deposition method to apply a luminophore on a porous anodized-aluminum surface, controlling the luminophore concentration of the dipping method to optimize AA-PSP characteristics. The concentration is varied from 0.001 to 10 mM. Characterizations include the pressure sensitivity, the temperature dependency, and the signal level. The pressure sensitivity shows around 60 % at a lower concentration up to 0.1 mM. Above this concentration, the sensitivity reduces to a half. The temperature dependency becomes more than a half by setting the luminophore concentration from 0.001 to 10 mM. There is 3.6-fold change in the signal level by varying the concentration. To discuss an optimum concentration, a weight coefficient is introduced. We can arbitrarily change the coefficients to create an optimized AA-PSP for our sensing purposes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Dipping Duration Study for Optimization of Anodized-Aluminum Pressure-Sensitive Paint

Anodized-aluminum pressure-sensitive paint (AA-PSP) uses the dipping deposition method to apply a luminophore on a porous anodized-aluminum surface. We study the dipping duration, one of the parameters of the dipping deposition related to the characterization of AA-PSP. The dipping duration was varied from 1 to 100,000 s. The properties characterized are the pressure sensitivity, temperature de...

متن کامل

Global Oxygen Detection in Water Using Luminescent Probe on Anodized Aluminum

We have developed anodized-aluminum pressure-sensitive paint (AA-PSP) as a global oxygen sensor in water. Platinum (II) meso-tetra(pentafluorophenyl)porphine is selected as a luminophore based on a dipping deposition study. The developed AA-PSP is characterized using water calibration setup by controlling dissolved oxygen concentration. It is shown that AA-PSP yields 4.0% change in luminescence...

متن کامل

Pressure-Sensitive Paint: Effect of Substrate

There are numerous ways in which pressure-sensitive paint can be applied to a surface. The choice of substrate and application method can greatly affect the results obtained. The current study examines the different methods of applying pressure-sensitive paint to a surface. One polymer-based and two porous substrates (anodized aluminum and thin-layer chromatography plates) are investigated and ...

متن کامل

Luminophore Application Study of Polymer-Ceramic Pressure-Sensitive Paint

A polymer-ceramic pressure-sensitive paint (PC-PSP) is a fast responding and sprayable PSP which has been applied for capturing global unsteady flows. The luminophore application process is studied to enhance the characterization of the PC-PSP. A dipping deposition method is used to apply a luminophore on a polymer-ceramic coating. The method selects a solvent by its polarity index. The charact...