Water pollutant monitoring by a whole cell array through lens-free detection on CCD.

نویسندگان

  • Hsieh-Fu Tsai
  • Yi-Ching Tsai
  • Sharon Yagur-Kroll
  • Noa Palevsky
  • Shimshon Belkin
  • Ji-Yen Cheng
چکیده

Environmental contamination has become a serious problem to human and environmental health, as exposure to a wide range of possible contaminants continuously increases due to industrial and agricultural activities. Whole cell sensors have been proposed as a powerful tool to detect class-specific toxicants based upon their biological activity and bioavailability. We demonstrated a robust toxicant detection platform based on a bioluminescence whole cell sensor array biochip (LumiChip). LumiChip harbors an integrated temperature control and a 16-member sensor array, as well as a simple but highly efficient luminescence collection setup. On LumiChip, samples were infused in an oxygen-permeable microfluidic flow channel to reach the sensor array. Time-lapse changes in bioluminescence emitted by the array members were measured on a single window-removed linear charge-coupled device (CCD) commonly used in commercial industrial process control or in barcode readers. Removal of the protective window on the linear CCD allowed lens-free direct interfacing of LumiChip to the CCD surface for measurement with high light collection efficiency. Bioluminescence induced by simulated contamination events was detected within 15 to 45 minutes. The portable LumiSense system utilizing the linear CCD in combination with the miniaturized LumiChip is a promising potential platform for on-site environmental monitoring of toxicant contamination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

امکان استفاده از آنزیم EcoR1 در طبقه بندی سویه های اکانتامبای ایزوله شده از التهاب قرنیه

Acanthamoeba keratitis is increasingly being diagnosed among people who wear thrapeutic and cosmetic contact lenses. The chain of events is thought to begin with contamination of the contact lens storage cases with Acanthamoeba from household or mains water supplies. If bacteria contamination is also present then these amoebas can multiply by ingesting the bacteria as a food source. If the cont...

متن کامل

A New Compact Ultra-wideband Linear Antenna Array for Target Detection Applications

This paper presents a low-cost compact planar microstrip-fed monopole antenna and its four-element array design for ultra-wideband (UWB) wireless communication and target detection applications, respectively, operating in the frequency span of 3 GHz to 11 GHz. A prototype was fabricated and then measured based on optimal parameters. The results of reflection coefficient (S11) and radiation patt...

متن کامل

Lasers and CCDs for flash measurement of small diameters

A pulsed diode laser casting a diffraction pattern shadow on a CCD is investigated as a non-contact micrometer. Data collected with a prototype instrument are compared with calculated diffraction patterns. Computational needs and possible techniques for diameter extraction are discussed. Background Laser micrometers have been available for several years. In the commercial instruments a rotating...

متن کامل

Whole column fluorescence imaging on a microchip by using a programmed organic light emitting diode array as a spatial-scanning light source and a single photomultiplier tube as detector.

A novel miniaturized, integrated whole-column imaging detection (WCID) system on a microchip is presented. In this system, a program controlled organic light emitting diode (OLED) array was used as a spatial-scanning light source, to achieve imaging by the time sequence of the excited fluorescence. By this mechanism, a photomultiplier tube (PMT) instead of a charge coupled detector (CCD) can be...

متن کامل

Make Wide-angled Aerial Camera by Combining Small-sized Areal Array Ccd Sensors

A new method for combining small-sized areal array CCD sensors to make one wide-angled digital aerial photography system is studied in this paper. The method is to install several small-sized areal array CCD cameras in the way that their perspective projecting centers form a line or a square, with their principal optical axes slanting fixed angle along designed directions. Such installation aim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 15 6  شماره 

صفحات  -

تاریخ انتشار 2015