Primary placement of a motility coupling post in porous polyethylene orbital implants.
نویسندگان
چکیده
The placement of a motility coupling post (MCP) to integrate the prosthesis with a porous orbital implant may enhance prosthetic motility following enucleation. Previously, MCP placement has required a second operation usually at least 6 months following enucleation. We developed a technique to place an MCP reliably and safely into a porous orbital implant at the time of enucleation. Eligibility criteria included high motivation to achieve maximal prosthetic motility, adequate conjunctiva to ensure desirable wound closure, and isolation of the 4 rectus muscles. Enucleation was performed in standard fashion with implantation of a conical porous polyethylene orbital implant. Implanted MCPs protruded anteriorly 2 to 4 mm. The Tenon capsule and conjunctiva were closed in separate layers over the protruding MCP. Thirty-two patients underwent primary placement. Follow-up ranged from 1 to 33 months (mean, 15 months). Nine MCPs spontaneously exposed within the first 4 months. One additional post autoexposed at 12 months. Three patients underwent a secondary procedure to expose the MCP. There were no cases of infection, explantation, or gross MCP malposition. Minor complications included pyogenic granuloma (n=2) and conjunctival overgrowth (n=1). All patients were successfully fit with prostheses. Prosthetic motility was acceptable in all patients. Motility coupling post placement at the time of enucleation surgery in selected patients is an effective, efficient surgical option. Arch Ophthalmol. 2000;118:826-832
منابع مشابه
Autogenous temporalis fascia patch graft for porous polyethylene (Medpor) sphere orbital implant exposure.
BACKGROUND Temporalis fascia has been recommended for hydroxyapatite sphere exposure. The aim of this study was to identify potential risk factors for exposure of porous polyethylene (Medpor) sphere implants and evaluate the use of autogenous temporalis fascia as a patch graft for exposure. METHODS A retrospective review of consecutive cases of porous polyethylene sphere orbital implant expos...
متن کاملArtificial eye amplitudes and characteristics in enucleated socket with porous polyethylene spherical and quad-motility implant.
PURPOSE To compare artificial eye amplitudes in enucleated socket with porous polyethylene either spherical or quad-motility implant and study the characteristics of artificial eyes fit with the two orbital implants. METHODS A total of 21 patients were prospectively studied who underwent enucleation because of an intraocular melanoma and the randomization defined a porous polyethylene either ...
متن کاملComplications in motility PEG placement for hydroxyapatite orbital implant in anophthalmic socket.
PURPOSE In a retrospective study, we evaluated the complications in using the motility peg system (nonsleeved and sleeved) for hydroxyapatite orbital implants in an anophthalmic socket. METHODS Drilling for motility peg placement was performed in 265 patients with hydroxyapatite implantation: nonsleeved peg system (n = 191), sleeved peg system (n = 74). A statistical analysis was performed us...
متن کاملMultipurpose conical orbital implant in evisceration.
PURPOSE To evaluate the safety and efficacy of the porous polyethylene multipurpose conical orbital implant for use in evisceration. METHODS A retrospective review of 31 eyes that underwent evisceration and received the multipurpose conical orbital implant. The orbits were evaluated at 1 week, 1 month, and 6 months after final prosthetic fitting for implant exposure, superior sulcus deformity...
متن کاملComplications of motility peg placement for porous hydroxyapatite orbital implants.
AIM To evaluate the complications associated with pegging of porous hydroxyapatite orbital implants. METHODS Complications associated with pegging were retrospectively reviewed from the charts of 100 of 133 patients with hydroxyapatite implantation from 1993 to 2000. RESULTS 48 (48%) of the 100 hydroxyapatite implanted patients who had undergone pegging were found to have problems with thei...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Archives of ophthalmology
دوره 118 6 شماره
صفحات -
تاریخ انتشار 2000