Improved detection of hypervascular liver lesions with CAIPIRINHA-Dixon-TWIST-volume-interpolated breath-hold examination.

نویسندگان

  • Philipp M Kazmierczak
  • Daniel Theisen
  • Kolja M Thierfelder
  • Wieland H Sommer
  • Maximilian F Reiser
  • Mike Notohamiprodjo
  • Konstantin Nikolaou
چکیده

OBJECTIVES The aim of this study was to assess the diagnostic performance of a dynamic, multiphasic contrast-enhanced volume-interpolated sequence with advanced parallel imaging techniques, Dixon fat saturation, and view sharing with 5 hepatic arterial subphases for the detection of focal liver lesions. MATERIALS AND METHODS Twenty-four consecutive patients (13 females, 11 males; mean [SD] age, 58 [15] years) with focal liver lesions were included in this prospective study. The examination was performed at a 3-T magnetic resonance imaging system (MAGNETOM Skyra; Siemens Healthcare, Erlangen, Germany). Five dynamic arterial subphases with a temporal resolution of 2.6 seconds, starting 17 seconds after injection of the hepatobiliary contrast agent gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Eovist; Bayer HealthCare, Leverkusen, Germany), were acquired using an accelerated parallel imaging volume-interpolated sequence with view sharing (multiarterial controlled aliasing in parallel imaging results in higher acceleration-Dixon-time-resolved angiography with interleaved stochastic trajectories-volumetric interpolated breath-hold examination [MA-CDT-VIBE]). The fourth of the 5 arterial acquisition phases (ie, at 24.8 seconds after the start of contrast agent injection) was considered the equivalent of a standard hepatic arterial phase (equivalent standard arterial phase [ESAP]). The diagnostic value of all 5 dynamic arterial phases for the detection of focal liver lesions, as compared with the single ESAP, was judged in 2 independent consensus readings. The 2 consensus reading groups were blinded to each others' results. The complete, comprehensive multisequence magnetic resonance imaging examination, including T1-weighted, T2-weighted, and multiphasic contrast-enhanced sequences, served as the standard of reference for lesion detection. RESULTS Forty-six percent of the patients (11/24) had hypervascular lesions. In 79 % of all patients (19/24), the best arterial parenchymal contrast of one of the MA-CDT-VIBE acquisition phases was considered better than that of the ESAP. In one third of all cases (8/24 for the first and 6/24 for the second consensus reading), MA-CDT-VIBE showed an improved lesion detection rate compared with ESAP, especially in hypervascular lesions (4/11, representing 36% of all patients with hypervascular lesions). There was a high degree of interrater agreement between the 2 consensus reading groups (the Cohen κ, 0.71-1.00; P < 0.001). CONCLUSIONS Compared with a standard hepatic arterial phase, MA-CDT-VIBE with 5 hepatic arterial subphases demonstrated greater diagnostic accuracy for the detection of hypervascular focal liver lesions and provided a robust and optimized hepatic arterial acquisition phase.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arterial Phase with CAIPIRINHA-Dixon-TWIST (CDT)–Volume-Interpolated Breath-Hold Examination (VIBE) in Detecting Hepatic Metastases

PURPOSE To evaluate lesion enhancement performance of Multi-Arterial CAIPIRINHA-Dixon-TWIST-Volume-Interpolated Breath-Hold Examination (MA-CDT-VIBE) for the detection of hepatic metastases. MATERIALS AND METHODS Thirty-one patients with suspicious hepatic metastases were enrolled in this retrospective study. Two independent radiologists scored visualization of each lesion on a scale of 1 (po...

متن کامل

Diagnosing Lung Nodules on Oncologic MR/PET Imaging: Comparison of Fast T1-Weighted Sequences and Influence of Image Acquisition in Inspiration and Expiration Breath-Hold

OBJECTIVE First, to investigate the diagnostic performance of fast T1-weighted sequences for lung nodule evaluation in oncologic magnetic resonance (MR)/positron emission tomography (PET). Second, to evaluate the influence of image acquisition in inspiration and expiration breath-hold on diagnostic performance. MATERIALS AND METHODS The study was approved by the local Institutional Review Boa...

متن کامل

Highly accelerated T1-weighted abdominal imaging using 2-dimensional controlled aliasing in parallel imaging results in higher acceleration: a comparison with generalized autocalibrating partially parallel acquisitions parallel imaging.

PURPOSE The purpose of this study was to evaluate the feasibility and technical quality of an abdominal 3-dimensional interpolated breath-hold (volumetric interpolated breath-hold examination [VIBE]) magnetic resonance examination using the new parallel acquisition technique, controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA). MATERIALS AND METHODS In this ins...

متن کامل

Use of a Two-point Dixon Vibe Sequence for Post-contrast Liver Mri: Comparison with Standard Chemically-selective Fat-suppressed Vibe for Image Quality and Lesion Detection

Introduction: Dynamic gadolinium-enhanced T1-weighted images are a critical component of clinical liver MRI examinations for focal lesion detection and characterization. This is typically performed as a 3D acquisition using chemically-selective fat-saturation, as demonstrated by the volumetric interpolated breath-hold examination (VIBE) sequence. A limitation of this approach is that chemically...

متن کامل

Rapid Cartesian versus radial acquisition: comparison of two sequences for hepatobiliary phase MRI at 3 tesla in patients with impaired breath-hold capabilities

BACKGROUND Hepatocyte-specific gadolinium based contrast agents (HSCA) provide substantial information for the classification of liver lesions in magnetic resonance imaging (MRI). However, breathing artifacts which reduce image quality and diagnostic confidence of hepatobiliary phase acquisitions are regularly observed in clinical routine. The aim of this study was to evaluate two approaches to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative radiology

دوره 50 3  شماره 

صفحات  -

تاریخ انتشار 2015