Comparison of visual field progression in patients with normal pressure glaucoma between eyes with and without visual field loss that threatens fixation.

نویسندگان

  • W L Membrey
  • D P Poinoosawmy
  • C Bunce
  • F W Fitzke
  • R A Hitchings
چکیده

AIM To compare the frequency and site of visual field progression and changes in visual acuity in patients with normal pressure glaucoma (NPG) with and without pre-existing visual field loss. METHOD Patients with normal tension glaucoma were selected who had at least 10 visual fields over 5 or more years of follow up and no other condition that might influence the visual field or visual acuity. Alternate left and right eyes were selected from patients in random order. These eyes were then subdivided according to visual field defect threatening fixation, visual field defect not threatening fixation, and no visual field defect (fellow eyes). Eyes were defined as showing a threat to fixation according to the presence of a visual field defect involving one of more of four paracentral visual field locations. Pointwise linear regression analysis was applied to each visual field series using PROGRESSOR software. Progression of visual field loss was defined as the appearance of a regression slope 1 dB per year or more with a significance of p<0.01, which remained consistent with the addition of two of three successive visual fields to the series. The number of patients showing progression and the number where progression occurred in one of the four paracentral visual field locations was noted. The number of eyes losing two or more lines of Snellen visual acuity over the follow up period was also noted. RESULTS 174 eyes of 174 patients were selected. 106 eyes had visual field loss threatening fixation, 46 eyes had visual field loss that did not threaten fixation, and 22 were fellow eyes with normal visual fields. The median follow up was 7.2 years. Eight eyes (36.4%) in the "normal visual fields" group, 31 eyes (67.4%) in the "visual field loss away from fixation" group, and 87 eyes (82.1%) in the "threat to fixation" group showed progression in any part of the visual field. Two eyes (9.1%) in the "normal visual fields" group, nine eyes (19.6%) in the "visual field loss away from fixation" group, and 45 eyes (42.5%) in the "threat to fixation" group showed progression at "threat to fixation". The Cox proportional hazards regression model showed an increased risk of progression at any part of the visual field for female sex and a decreased risk for eyes with normal visual fields. For progression at threat to fixation this model showed an increased risk with pre-existing threat to fixation. Eyes from older patients and those that went on to have progressive visual field loss at fixation were more likely to lose two lines of Snellen visual acuity over the follow up period. CONCLUSION Since 20-30% of previously field damaged eyes and over 60% without prior field loss fail to demonstrate progressive visual field damage over a long follow up it is recommended that normal pressure glaucoma patients be monitored for progression and that potentially harmful therapy be withheld until progression is demonstrated. Although the presence of visual field loss that threatens fixation does not constitute an increased risk of visual field progression it does indicate an increased risk of further loss of visual field close to fixation which is in turn associated with loss of central acuity. In the light of this finding, patients with visual field loss that threatens fixation should be managed more aggressively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the effects of glaucomatous (POAG) damage on the mVEP parameters

Introduction: Glaucoma is considered as a major cause of irreversible vision loss, worldwide. Glaucoma includes a diverse ophthalmopathies characterized by attenuating the neural and connective tissue segments and eventually progression of specific patterns of visual dysfunction. Currently, perimetry is known as the most accurate diagnostic method in glaucoma and its follow up...

متن کامل

Relationship between progression of visual field defect and intraocular pressure in primary open-angle glaucoma

PURPOSE To analyze the relationship between intraocular pressure (IOP) and the progression of visual field defects in Japanese primary open-angle glaucoma (POAG) and normal-tension glaucoma (NTG) patients. PATIENTS AND METHODS The subjects of the study were patients undergoing treatment for POAG or NTG who had performed visual field tests at least ten times with a Humphrey field analyzer (Swe...

متن کامل

Fellow eye prognosis in patients with severe visual field loss in 1 eye from chronic open-angle glaucoma.

OBJECTIVES To examine the prognosis for the fellow eye of patients with severe visual field loss in 1 eye from chronic forms of open-angle glaucoma, and to identify risk factors for visual field progression in such eyes. METHODS Review of 36 patients followed in an academic medical center with monocular severe visual field loss (Advanced Glaucoma Intervention Study score > or =12) from open-a...

متن کامل

گزارش یک مورد کاهش بینایی شدید یکطرفه و کاپینگ دو طرفه عصب اپتیک ثانویه به تومورمتاستاتیک مغز

Purpose: To report a case of unilateral severe visual loss and bilateral optic disc cupping secondary to brain metastasis of bronchogenic carcinoma Patient and findings: A 48 year-old woman presented with severe visual loss of left eye without redness or pain or any systemic findings .Clinical findings included decreased visual acuity of left eye to 4 m CF and (+3) positive Marcus-Gunn refle...

متن کامل

The relation between intraocular pressure peak in the water drinking test and visual field progression in glaucoma.

AIM To compare the results of the water drinking test between glaucomatous eyes with and without visual field progression. METHODS Retrospective analysis of 76 eyes of 76 open angle glaucoma patients followed for a mean period of 26.0 (SD 13.8) months. Patients were submitted to the water drinking test at the beginning of the follow up period. Reliable achromatic automated perimetry tests per...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 84 10  شماره 

صفحات  -

تاریخ انتشار 2000