Macular pigment density measured by autofluorescence spectrometry: comparison with reflectometry and heterochromatic flicker photometry.
نویسندگان
چکیده
We present a technique for estimating the density of the human macular pigment noninvasively that takes advantage of the autofluorescence of lipofuscin, which is normally present in the human retinal pigment epithelium. By measuring the intensity of fluorescence at 710 nm, where macular pigment has essentially zero absorption, and stimulating the fluorescence with two wavelengths, one well absorbed by macular pigment and the other minimally absorbed by macular pigment, we can make accurate single-pass measurements of the macular pigment density. We used the technique to measure macular pigment density in a group of 159 subjects with normal retinal status ranging in age between 15 and 80 years. Average macular pigment density was 0.48 +/- 0.16 density unit (D.U.) for a 2 degrees -diameter test field. We show that these estimates are highly correlated with reflectometric (mean: 0.23 +/- 0.07 D.U.) and psychophysical (mean: 0.37 +/- 0.26 D.U.; obtained by heterochromatic flicker photometry) estimates of macular pigment in the same subjects, despite the fact that systematic differences in the estimated density exist between techniques. Repeat measurements over both short- and long-time intervals indicate that the autofluorescence technique is reproducible: The mean absolute difference between estimates was less than 0.05 D.U., superior to the reproducibility obtained by reflectometry and flicker photometry. To understand the systematic differences between density estimates obtained from the different methods, we analyzed the underlying assumptions of each technique. Specifically, we looked at the effect of self-screening by visual pigment, the effect of changes in optical property of the deeper retinal layers, including the role of retinal pigmented epithelium melanin, and the role of secondary fluorophores and reflectors in the anterior layers of the retina.
منابع مشابه
Comparison between macular pigment optical density measurements using two-wavelength autofluorescence and heterochromatic flicker photometry techniques.
PURPOSE The association of macular pigment (MP) with age-related macular degeneration has been extensively studied in recent years, and interest in a rapid, objective, and accurate technique to measure MP optical density (MPOD) has increased. The purpose of this study was to compare the MPOD values at specific loci around the fovea using the heterochromatic flicker photometry (HFP) and the two-...
متن کاملMacular Pigment Optical Density Measured by Heterochromatic Modulation Photometry
PURPOSE To psychophysically determine macular pigment optical density (MPOD) employing the heterochromatic modulation photometry (HMP) paradigm by estimating 460 nm absorption at central and peripheral retinal locations. METHODS For the HMP measurements, two lights (B: 460 nm and R: 660 nm) were presented in a test field and were modulated in counterphase at medium or high frequencies. The co...
متن کاملMacular pigment optical density spatial distribution measured in a subject with oculocutaneous albinism.
PURPOSE Previous studies of macular pigment optical density (MPOD) distribution in individuals with oculocutaneous albinism (OCA) have primarily used objective measurement techniques including fundus reflectometry and autofluorescence. We report here on a subject with OCA and their corresponding MPOD distribution assessed through heterochromatic flicker photometry (HFP). METHODS A subject wit...
متن کاملClinical and Epidemiologic Research The Heritability of Macular Response to Supplemental Lutein and Zeaxanthin: A Classic Twin Study
METHODS. A total of 322 healthy female twin volunteers, aged 16–50 years (mean 40 6 8.7) was enrolled in a prospective, nonrandomized supplement study. Macular pigment optical density (MPOD) measurements using two techniques (2wavelength fundus autofluorescence [AF] and heterochromatic flicker photometry [HFP]), and serum concentrations of L and Z, were recorded at baseline, and at 3 and 6 mont...
متن کاملAn exploratory study evaluating the effects of macular carotenoid supplementation in various retinal diseases
PURPOSE The aim of this study was to assess the impact of daily oral supplementation with Macushield (10 mg/d meso-zeaxanthin, 10 mg/d lutein, and 2 mg/d zeaxanthin) on eye health in patients with retinal diseases by assessing the macular pigment (MP) profile, the visual function, and the quality of life. METHODS Fifty-one patients with various retinal diseases were supplemented daily and fol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the Optical Society of America. A, Optics, image science, and vision
دوره 18 6 شماره
صفحات -
تاریخ انتشار 2001