Polycapillary X-ray optics for microdiffraction

نویسندگان

  • C. A. MacDonald
  • S. M. Owens
چکیده

Polycapillary optics, i.e. shaped arrays consisting of hundreds of thousands of hollow glass capillary tubes, can be used to redirect, collimate or focus X-ray beams. X-rays emitted over a large angular range from conventional laboratory-based sources can be transformed into a beam with a small angular divergence or focused onto a small sample or sample area. Convergent beams of X-rays, with convergence angles as high as 15 , have been produced using polycapillary X-ray optics. Focused-spot sizes as small as 20 mm have been achieved, with ̄ux densities two orders of magnitude larger than that produced by pinhole collimation. This results in a comparable decrease in data collection times because of the increase in direct-beam intensity and reciprocal-space coverage. In addition, the optics can be employed to reduce background and provide more convenient alignment geometries. The inverse dependence of the critical angle for total external re ̄ection on photon energy results in suppression of high-energy photons. This effect can be employed to allow the use of higher tube potentials to increase the characteristic line emission and has also been employed to increase signi®cantly the K /K ratio in Cu radiation. Measurements of X-ray diffraction data and crystallographic analyses have been performed for systems ranging from elemental crystals to proteins. Data from a lysozyme protein `standard' with a slightly convergent beam, taken in 3 min per frame with 2 oscillation with a 2.8 kW source, re®ned to an intensity variance of 5% compared to a standard data set. High-quality data were also obtained with a 0.03 kW ®xed-anode source and a 2 convergent lens in 5 min per frame.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Framework for computing the spatial coherence effects of polycapillary x-ray optics

Despite the extensive use of polycapillary x-ray optics for focusing and collimating applications, there remains a significant need for characterization of the coherence properties of the output wavefield. In this work, we present the first quantitative computational method for calculation of the spatial coherence effects of polycapillary x-ray optical devices. This method employs the coherent ...

متن کامل

Full-field transmission x-ray imaging with confocal polycapillary x-ray optics.

A transmission x-ray imaging setup based on a confocal combination of a polycapillary focusing x-ray optic followed by a polycapillary collimating x-ray optic was designed and demonstrated to have good resolution, better than the unmagnified pixel size and unlimited by the x-ray tube spot size. This imaging setup has potential application in x-ray imaging for small samples, for example, for his...

متن کامل

Focusing Polycapillary Optics and Their Applications

A summary of focusing X ray polycapillary optics is presented including history, theory, modeling, and applications development. The focusing effects of polycapillary optics come from the overlap of the beams from thousands of small hollow glass tubes. Modeling efforts accurately describe optics performance to allow for system development in a wide variety of geometries. The focusing of X ray b...

متن کامل

Grid-enhanced X-ray coded aperture microscopy with polycapillary optics

Polycapillary devices focus X-rays by means of multiple reflections of X-rays in arrays of bent glass capillaries. The size of the focal spot (typically 10-100 μm) limits the resolution of scanning, absorption and phase-contrast X-ray imaging using these devices. At the expense of a moderate resolution, polycapillary elements provide high intensity and are frequently used for X-ray micro-imagin...

متن کامل

Performance study of polycapillary optics for hard x rays

In order to investigate the feasibility of using Kumakhov capillary x-ray optics for high energy x-ray applications, measurements have been performed on the behavior of capillary optics from 10 to 80 keV. Transmission efficiencies of straight polycapillary fibers of different types have been measured as a function of source location and x-ray energy. The measurements are analyzed using a geomet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999