A Cascaded Dual Buck Half-Bridge Inverter for Efficient Power Flow Control in Grid

نویسندگان

  • S. Saravana Kiruthiga
  • S. Rajasekaran
چکیده

This paper presents a single phase 7-level half bridge cascade dual buck multilevel grid-tied inverter with both active and reactive power flow control in a wide range under two types of renewable energy. The power flow is controlled by varying the switching pulse of the power semiconductor device used in the half bridge cascade dual buck multilevel grid-tie inverter. The multicarrier sinusoidal pulse width modulation (SPWM) is used by which the power angle can be varied, by changing the switching pulse. By varying the power angle, the voltage and current at the grid side is changed. Active and Reactive power consumed or injected by each unit is depending on the shift angle between the current and modulated voltage in the each single unit of cascade dual buck inverter. Thus by varying the power angle, the power flow can be controlled effectively. The Total Harmonic Distortion (THD) is reduced, when compared with the 11-level cascade H-bridge grid-tie inverter. This is proved by using FFT analysis in MATLAB SIMULINK. The simulation is carried out for both type I and type II system in MATLAB SIMULINK. The experimental results have proved the effectiveness of the designed grid-tie control for both type I and type II system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unified Constant-frequency Integration control of Three-phase Grid-connected Inverter for Alternative Energy Power Generation

Abstract-A new control approach for three-phase gridconnected inverters is presented. The inverter stage is a standard three-phase half bridge. During each 60° of line cycle, the three-phase half bridge can be de-coupled into parallel-connected a dual-buck inverter. Based on Onecycle control, a Unified Constant-frequency Integration controller (UCI) is proposed for the dual-buck inverter. The c...

متن کامل

A Novel Controller Based on Single-Phase Instantaneous p-q Power Theory for a Cascaded PWM Transformer-less STATCOM for Voltage Regulation

In this paper, dynamic performance of a transformerless cascaded PWM static synchronous shunt compensator (STATCOM) based on a novel control scheme is investigated for bus voltage regulation in a 6.6kV distribution system. The transformerless STATCOM consists of a thirteen-level cascaded H-bridge inverter, in which each voltage source H-bridge inverter should be equipped with a floating and iso...

متن کامل

استفاده از اینورتر چندسطحی با کنترل‌کننده غیرخطی مستقیم برای اتصال مزرعه خورشیدی به شبکه

The solar photovoltaic (PV) farm delivers its harvested DC energy to the AC grid via power electronic interfaces. With insolation as well as ambient temperature variations, these power electronic converters should regulate operating point at optimal point to extracting maximum power from PV cells. In this paper, a direct nonlinear control method is developed for cascaded H-bridge multilevel inv...

متن کامل

Harmonic Reduction Using Multilevel Inverter Concepts

Solar energy sources are widely available, but in the form of DC source. It is connected in distribution system by means of converting DC/AC supply. It is achieved by means of inverter. To get efficient AC source we use multilevel inverter (MLI). The popularly used inverter is cascaded H-bridge MLI. As the step increases, the AC output nearly becomes same as sinusoidal. The purpose of the proje...

متن کامل

Compensation of Voltage and Current Harmonics in Hybrid Renewable Energy System Using Coordinated Power Control of RES Inverter

In this paper, an adaptive control strategy is proposed for the inverters of renewable energy source (RES) to simultaneously control the load voltage, grid current and the amount of instantaneous injected power to the grid in the presence of grid voltage distortions and nonlinearity of load current. In the proposed control strategy, the power quality of the local load can be settled based on th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014