Refractive index change in bovine and human corneal stroma before and after lasik: a study of untreated and re-treated corneas implicating stromal hydration.

نویسندگان

  • Sudhir Patel
  • Jorge L Alió
  • Juan J Pérez-Santonja
چکیده

PURPOSE To measure the refractive index (RI) of the mammalian corneal stroma in relation to hydration in vitro and human corneal stroma before and after LASIK. METHODS RI at the anterior stromal surface of bovine corneal buttons was measured after the epithelium was scraped away. Samples were weighed and oven dried to calculate hydration. RI of the stromal bed surface was measured with a modified hand-held Abbé refractometer immediately before and after excimer laser photoablation. Thirty-one untreated persons (group 1: 44 corneas; age range, 19-65 years) and eight re-treated patients (group 2: 10 corneas) were examined. RESULTS RI of bovine stromal surface was significantly associated with hydration (H) (RI = 1.4067 - 0.00599H, r = -0.9079, P < 0.001). Photoablation significantly increased the RI of the midstroma (group 1: 1.3721 +/- 0.0041 to 1.3839 +/- 0.0050; group 2: 1.3717 +/- 0.0038 to 1.3819 +/- 0.0039). Differences between groups were not significant. In group 1 (n = 31), change in RI (DeltaRI) was significantly related to preoperative RI (DeltaRI = 1.155 - 0.833RI, r = 0.595, P < 0.001) and RI was significantly related to age (x) (RI = 1.3634 + 0.00026x, r = 0.603, P < 0.001). CONCLUSIONS Mammalian corneal stromal RI correlates with hydration. LASIK significantly increases the refractive index of the treated stromal bed, and this equates to an average change in hydration from 4.3 to 2.9. For individual cases, change in RI is associated with the pre-op RI. The lack of any difference between untreated and re-treated corneas suggests that with time hydration returns back to normal levels. The RI in the older corneal stroma is slightly higher relative to the RI in the younger corneal stroma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standardization of corneal haze measurement in confocal microscopy.

PURPOSE Corneal stromal haze cannot be compared in longitudinal studies or across laboratories without standardization. In this study, a method was devised of standardizing image brightness in confocal microscopy of the cornea. METHODS Thirty-six normal corneas of 18 untreated volunteers and 35 corneas of 18 patients 3 years after LASIK were examined by slit scanning confocal microscopy. The ...

متن کامل

The specific architecture of the anterior stroma accounts for maintenance of corneal curvature.

AIM To analyse the human corneal stroma in extreme hydration to discover if its structure is responsible for corneal stability. METHODS Corneas in several hydration states were used: postmortem control corneas (PM; n=3), corneas left for 1 day in phosphate buffered saline (PBS; n=4), and corneas left for 1 day (n=4), 2 days (n=4), 3 days (n=2), and 4 days (n=4) in deionised water. All corneas...

متن کامل

Hyaluronidase treatment, collagen fibril packing, and normal transparency in rabbit corneas.

PURPOSE Hyaluronidase treatment is the initial step of corneaplasty, a treatment under development that induces stromal softening and involves the application of a custom designed forming lens to achieve modification of refractive error. The purpose of this investigation was to examine changes in the arrangement of stromal collagen fibrils after hyaluronidase treatment. METHODS Rabbit corneas...

متن کامل

Influence of corneal collagen crosslinking with riboflavin and ultraviolet-a irradiation on excimer laser surgery.

PURPOSE Riboflavin/ultraviolet A (UVA) cross-linking (CXL) of corneal collagen is a novel method of stabilizing corneal mechanical properties and preventing progression of keratectasias. This study was conducted to investigate whether CXL influences ablation rate, flap thickness, and refractive results of excimer laser procedures ex vivo. METHODS Corneal epithelium was removed from enucleated...

متن کامل

Swelling studies of camel and bovine corneal stroma

In the present study we investigated the swelling characteristics of fresh camel and bovine cornea in sodium salt solutions. Swelling studies were carried out at 20 minutes, 14 hours, and 46 hours on five fresh camel and 5 five fresh bovine corneas. During the 20-minute hydration of fresh corneal stroma was investigated using sodium chloride (NaCl), sodium bicarbonate (NaHCO(3)), sodium acetate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 45 10  شماره 

صفحات  -

تاریخ انتشار 2004