Reduction of excessive electrical stimulus during electric pulp testing.

نویسندگان

  • K C Nam
  • S H Ahn
  • J H Cho
  • D W Kim
  • S J Lee
چکیده

AIM To measure excessive electrical stimulus time during pulp testing via electromyography (EMG) in the anterior belly of the digastric muscle, voice and finger movement, and to determine whether excessive stimulus time could be attenuated by a specially designed automatic circuit breaker on the basis of the EMG signal. METHODOLOGY The signals from three human responses (EMG, finger and voice), induced by the Digitest (Parkell Inc., Farmingdale, NY, USA) electric pulp tester, were captured using a MP100 (Biopac System Inc., Goleta, CA, USA) and recorded into a personal computer. The excessive stimulus time from activation to the end of electrical stimulation was calculated for each of these three responses. The automatic circuit breaker was designed to disconnect the electrical output of the electric pulp testing (EPT) unit immediately after detecting the preset EMG level (100 mV). Each of the right central incisors and first premolars of 23 healthy individuals (16 males and seven females) was tested to see whether there was a difference in tooth type or gender. This was analysed by Wilcoxon signed rank test (nonparametric paired t-test) and Mann-Whitney test (nonparametric independent t-test), respectively. RESULTS Amongst three human responses, the electrical onset occurred in the order of EMG, finger and voice. Excessive stimulus time was 347.8 +/- 78.3 ms when observed by the EMG, 264.9 +/- 63.9 ms when observed by finger span and 229.4 +/- 41.8 ms when observed by the voice, which were all found to be significantly different (P < 0.05). When the automatic circuit breaker was used, the excessive stimulus time was 61.0 ms, which was 286.8 ms shorter than that measured from EMG onset when using the conventional EPT. CONCLUSIONS When the automatic circuit breaker was used, excessive stimulus time on the basis of EMG was attenuated on average by 286.8 ms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی تاثیر تغییرات حرارتی بر پاسخ دندان به پالپ تستر الکتریکی

Background and Aims: The vitality pulp tests are necessary for diagnosis of pulpal disease and differentiation between endodontic and non-endodontic diseases. Thermal and electrical tests are conventional methods for evaluation of pulp vitality. The purpose of this study was to evaluate the effect of thermal changes on the tooth response to the electric pulp tester. Materials and Methods: In t...

متن کامل

بررسی اثر محل قرارگیری الکترود پالپ تستر در پاسخ دندان‌های قدامی فک بالا

Background and Aims: Electric pulp testing is used for diagnosis of the pulp status. This test is technique sensitive and hence may elicit positive or negative false response in case of inaccurate use. The optimal site for placement of the probe tip has not been determined. The aim of this study was to evaluate the effect of pulp tester probe placement site on the response of maxillary teeth.Ma...

متن کامل

Primary somatosensory cortical neuronal activity during monkey's detection of perceived change in tooth-pulp stimulus intensity.

To elucidate the functional properties of primary somatosensory cortical neurons for the perception of tooth-pulp sensation, neuronal activity was recorded from the primary somatosensory cortex (SI) in awake behaving monkeys. Monkeys were trained to detect changes in tooth-pulp stimulus intensity applied to the upper canine or incisor tooth pulp. Stimulus intensities applied to the tooth pulp w...

متن کامل

Application of Demand Response Programs to Heavy Industries: a Case Study on a Regional Electric Company

In recent years, incremental rate of electrical demands made many challenges for policy makers of power systems. Besides, due to economic crisis and environmental concerns about the air pollution, the new investments in thermal power generation units have experienced a noticeable reduction. For this reason, the power system operators should propose novel approaches to make a balance between inc...

متن کامل

A determination of the sensitivity of the dental pulp of primary maxillary anterior teeth to electrical stimuli in children with unilateral and bilateral clefts.

A study was conducted to determine differences in pulpal sensitivity of the maxillary primary anterior teeth in groups of children with unilateral clefts of the lip, alveolar process and palate, bilateral clefts of the lip process, and children without clefts. Thirty-nine children between the ages of 4 and 5 years with a total of 216 maxillary primary anterior teeth were tested using a pulp tes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International endodontic journal

دوره 38 8  شماره 

صفحات  -

تاریخ انتشار 2005