Ultra-high field upper extremity peripheral nerve and non-contrast enhanced vascular imaging
نویسندگان
چکیده
OBJECTIVE The purpose of this study was to explore the efficacy of Ultra-high field [UHF] 7 Tesla [T] MRI as compared to 3T MRI in non-contrast enhanced [nCE] imaging of structural anatomy in the elbow, forearm, and hand [upper extremity]. MATERIALS AND METHOD A wide range of sequences including T1 weighted [T1] volumetric interpolate breath-hold exam [VIBE], T2 weighted [T2] double-echo steady state [DESS], susceptibility weighted imaging [SWI], time-of-flight [TOF], diffusion tensor imaging [DTI], and diffusion spectrum imaging [DSI] were optimized and incorporated with a radiofrequency [RF] coil system composed of a transverse electromagnetic [TEM] transmit coil combined with an 8-channel receive-only array for 7T upper extremity [UE] imaging. In addition, Siemens optimized protocol/sequences were used on a 3T scanner and the resulting images from T1 VIBE and T2 DESS were compared to that obtained at 7T qualitatively and quantitatively [SWI was only qualitatively compared]. DSI studio was utilized to identify nerves based on analysis of diffusion weighted derived fractional anisotropy images. Images of forearm vasculature were extracted using a paint grow manual segmentation method based on MIPAV [Medical Image Processing, Analysis, and Visualization]. RESULTS High resolution and high quality signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]-images of the hand, forearm, and elbow were acquired with nearly homogeneous 7T excitation. Measured [performed on the T1 VIBE and T2 DESS sequences] SNR and CNR values were almost doubled at 7T vs. 3T. Cartilage, synovial fluid and tendon structures could be seen with higher clarity in the 7T T1 and T2 weighted images. SWI allowed high resolution and better quality imaging of large and medium sized arteries and veins, capillary networks and arteriovenous anastomoses at 7T when compared to 3T. 7T diffusion weighted sequence [not performed at 3T] demonstrates that the forearm nerves are clearly delineated by fiber tractography. The proper digital palmar arteries and superficial palmar arch could also be clearly visualized using TOF nCE 7T MRI. CONCLUSION Ultra-high resolution neurovascular imaging in upper extremities is possible at 7T without use of renal toxic intravenous contrast. 7T MRI can provide superior peripheral nerve [based on fiber anisotropy and diffusion coefficient parameters derived from diffusion tensor/spectrum imaging] and vascular [nCE MRA and vessel segmentation] imaging.
منابع مشابه
Exploring Peripheral Nerve, Macro and Micro-Vasculature Imaging Applications at Ultra-High Field MRI.
INTRODUCTION: Objective, non-invasive, sequential monitoring of peripheral nerve(PN) regeneration and revascularization after surgery is critical for evaluation of the efficacy of re-innervation and treatment strategies that may have important implications in recovery and outcome in PN/vessel injury as well as in VCA. For the first time, our group built a forearm/hand MRI coil for 7 Tesla MRI t...
متن کاملA Vascular Malformation Presenting as a Peripheral Nerve Sheath Tumor.
We present the case of a venous malformation (VM) masquerading as a schwannoma. VMs are thin-walled vascular dilations of various sizes that typically present as soft, compressible, blue masses that are associated with pain or dysesthesia. VMs are commonly found in the head and neck as well as the distal extremities. Notably, slow-flow VMs are hypointense on T1-weighted imaging, hyperintense on...
متن کاملComparison Between Three-Dimensional Diffusion-Weighted PSIF Technique and Routine Imaging Sequences in Evaluation of Peripheral Nerves in Healthy People
Introduction: The present study aims to evaluate the Three-Dimensional Diffusion-Weighted reversed fast imaging with steady state free precession (3D DW-PSIF) sequence with respect to imaging of the peripheral nerves; the tibial, medial, and lateral plantar nerves in the lower extremity, ulnar and median nerve in the upper extremity, sciatic nerve, brachial plexus, and lumbosacral plexus, and a...
متن کاملA rare type of peripheral nerve sheath tumor: radial nerve schwannoma.
Schwannomas, also known as neurilemmomas, are generally benign peripheral nerve sheath tumors developing from Schwann cells. Peripheral nerve sheath tumors account for less than 8% of soft tissue neoplasms. Schwannomas are characterized by a slow-growing and non-infiltrating pattern. We report a 21-year-old, right-handed male, with a mass at his right elbow anterolateral region, that was slowly...
متن کاملUltra-High-Field MR Neuroimaging.
At ultra-high magnetic fields, such as 7T, MR imaging can noninvasively visualize the brain in unprecedented detail and through enhanced contrast mechanisms. The increased SNR and enhanced contrast available at 7T enable higher resolution anatomic and vascular imaging. Greater spectral separation improves detection and characterization of metabolites in spectroscopic imaging. Enhanced blood oxy...
متن کامل