Influence of cabin conditions on placement and response of contaminant detection sensors in a commercial aircraft.
نویسندگان
چکیده
Potential causalities due to airborne disease transmission and risk of chem-bio terrorism in commercial airliner cabins can be reduced by fast responses. Fast responses are only possible by using sensors at appropriate locations in the cabins. Cost, size and weight factors restrict the number of sensors that could be installed inside a cabin. Since release locations and seating patterns of passengers can impact airborne contaminant transports, this study first addressed this impact by using a validated computational fluid dynamics (CFD) program in a four-row mockup of twin-aisle airliner cabin. It was observed that occupancy patterns and release locations have little influence on longitudinal contaminant transports though localized variations of contaminant concentrations may exist. The results show that response time of the sensors is considerably reduced with the increase in number of sensors. If only a single sensor is available across a cabin cross-section then it should be placed at the middle of the ceiling. A cabin model of a fully occupied twin-aisle airliner with 210 seats was also build to study the diverse contaminant distribution trends along cabin length. The results reveal that seating arrangements can make cross-sectional airflow pattern considerably asymmetrical. Similar airflow patterns make the longitudinal contaminant transport in the business and economy classes alike. The presence of galleys greatly affected the longitudinal transport of contaminants in a particular cabin section. The effects due to galleys were less significant if a multipoint sampling system was used. The multipoint sampling system can also reduce the number of sensors required in a cabin.
منابع مشابه
Experimental studies of thermal environment and contaminant transport in a commercial aircraft cabin with gaspers on.
Gaspers installed in commercial airliner cabins are used to improve passengers' thermal comfort. To understand the impact of gasper airflow on the air quality in a cabin, this investigation measured the distributions of air velocity, air temperature, and gaseous contaminant concentration in five rows of the economy-class section of an MD-82 commercial aircraft. The gaseous contaminant was simul...
متن کاملDesign and Experimental Analysis of Aircraft Air Distribution Systema
In this paper, the methodology of aircraft air distribution system has been analyzed theoretically and experimentally. To achieve that, ducting pressure loss and air flow throw gaspers calculations has been done for cabin ducts in according to exact location of individual air distribution system in the cabin. The length of gasper air flow was compared with the distance between gasper outlet and...
متن کاملSimulation-based Vibration Sensor Placement for Centrifugal Pump Impeller Fault Detection
In this paper, a simulation-based method is proposed for optimal placement of vibration sensors for the purpose of fault detection in a centrifugal pump. The centrifugal pump is modeled to investigate the effect of vane tip fault on fluid flow patterns numerically. Pressure pulsations are investigated at different locations at the inner surface of the pump before and after the presence of the f...
متن کاملComprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine 1262 Cabin Air Quality in Commercial Aircraft
Lindgren T. Cabin Air Quality in Commercial Aircraft Exposure, Symptoms and Signs. Comprehensive Summaries of Dissertations from the Faculty of Medicine. MEDFARM 2003/564. Uppsala. ISBN 91-554-5631-6 The objective of the dissertation was to study the cabin environment, and identify personal and environmental risk factors, associated with symptoms, and perception of cabin air quality. Another ob...
متن کاملAn Analysis on the Detection of Biological Contaminants Aboard Aircraft
The spread of infectious disease via commercial airliner travel is a significant and realistic threat. To shed some light on the feasibility of detecting airborne pathogens, a sensor integration study has been conducted and computational investigations of contaminant transport in an aircraft cabin have been performed. Our study took into consideration sensor sensitivity as well as the time-to-a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of environmental monitoring : JEM
دوره 10 1 شماره
صفحات -
تاریخ انتشار 2008