The comparison of the wear behavior of four different types of crosslinked acetabular components.

نویسنده

  • O K Muratoglu
چکیده

Introduction: Crosslinking of polyethylene has been known for decades to improve the abrasion resistance of the polymer for industrial applications. However, only three applications of this technology have been reported in use in total hip replacements in the orthopaedics literature by Grobbelaar et. al. [1], Oonishi et. al. [2], and Wroblewski et. al. [3]. Recently, the interest in highly crosslinked UHMWPEs increased, due largely to the demonstration by several investigators that crosslinking can markedly improve the wear resistance of UHMWPE in hip simulators [4-5]. Today there are four different types of low wear UHMWPE acetabular components available or in process to become available to the orthopaedic surgeon, namely CrossfireTM from Osteonics/Howmedica, MarathonTM from DePuy/J&J, LongevityTM from Zimmer, and DurasulTM from Sulzer. These components are all crosslinked using different techniques and different radiation dose level, which lead to different degrees of improvement in wear resistance. In this study, we have evaluated the wear behavior of the four types of low wear, crosslinked UHMWPEs prepared for use in total hip replacements, before and after artificial aging Materials and Methods: The crosslinked UHMWPEs studied were either the commercial product or a replica of the described technique to produce: (i) CrossfireTM:, (ii) MarathonTM, (iii) LongevityTM, and (iv) DurasulTM. The following descriptions for the manufacturing details of each crosslinked UHMWPE are according to their corresponding manufacturer: (i) CrossfireTM (Osteonics) is UHMWPE irradiated with gamma rays to 7.5 Mrad, annealed below the melt temperature, machined, packaged, and sterilized with gamma radiation (2.5 Mrad) in an inert gas; (ii) MarathonTM (DePuy) is UHMWPE irradiated with gamma rays to 5 Mrad, annealed above the melting temperature (150°C), machined, packaged, and sterilized with gas plasma; (iii) LongevityTM (Zimmer) is UHMWPE irradiated with 10 MeV electron-beam to 10 Mrad, machined, packaged, and sterilized with gas plasma; (iv) DurasulTM (Sulzer) is UHMWPE warm-irradiated with 10 MeV electron-beam to 9.5 Mrad, machined, packaged, and sterilized with ethylene oxide. Except MarathonTM, all the other crosslinked UHMWPEs were obtained from the manufacturers. The Marathon type material was manufactured by us, following the descriptions reported by the manufacturer (6). As control samples, we used conventional UHMWPE sterilized with 2.5 Mrad of gamma irradiation in nitrogen. All samples were machined into pins (diameter=9mm and height=13mm). Some of the pins of each material were artificially aged in an air convection oven at 80°C for three weeks. Three aged and three unaged pins from each series were wear tested. The wear tests were carried out in a bi-directional pin-on-disc machine by rubbing the pins against an implant finish Co-Cr disk through a rectangular path with a peak contact stress of 5MPa at a frequency of 2 Hz. The lubricant was 100% bovine serum. The tests were carried out to at least 2 and at most 5 million cycles (MC) with a gravimetric assessment of wear at every 0.5 million cycles. Some of the aged pins were sacrificed to determine the oxidation levels using a BioRad UMA 500 infra-red microscope as a function of depth away from the articulating surfaces. The oxidation index values were calculated by using the preferred method described by the ASTM F04.15.12 Task Force by normalizing the area under the carbonyl peak with the area under the 1370 cm methylene vibration. The infra-red analyses were performed before any aging and every week during the artificial aging process up to three weeks. Results: Figure 1 shows the wear rate comparison of the series studied here. The wear rate of the unaged pins showed significant improvement in wear rate compared to conventional polyethylene (Control) as a function of increasing dose level. The wear rate of unaged CrossfireTM, LongevityTM, and DurasulTM were about 1.4 mg/MC compared to the wear rate of unaged Marathon type material at 4.5±0.2 mg/MC and control pins at 9.4±1 mg/MC. After the artificial aging, the wear behavior of the LongevityTM, DurasulTM, and Marathon type material were unchanged. On the other hand, the wear rate of the control increased from 9.4±1 to 14±1 mg/MC. To our surprise, the wear rate of the aged CrossfireTM pins (28±6mg/MC) was higher than that observed in aged control pins. Figure 2 depicts the oxidation profile in each series after the third week of aging, which represents the oxidation state of the pins right before the POD wear testing. The Marathon type material, LongevityTM, and DurasulTM pins did not oxidize following the artificial aging cycle. The control pins showed a subsurface oxidation index of 0.4. The CrossfireTM pins displayed the highest level of subsurface oxidation at 1.7. Discussion: The wear rate of unaged Marathon type material was higher than that of unaged DurasulTM, LongevityTM, and CrossfireTM due to the lower radiation dose level used in the manufacture of Marathon type material. Reported data by the originators of Marathon material on hip simulator tests also show detectable wear [5]. The radiation dose levels in LongevityTM, DurasulTM, and Crossfire are around 10 Mrad; therefore they displayed equivalent wear rates in their unaged forms. Upon artificial aging the Marathon type material, DurasulTM, and LongevityTM did not show any appreciable oxidation and hence no change in their wear behavior because the ethylene oxide and gas plasma sterilization techniques used with these polymers have no long-term deleterious effects on the properties of UHMWPE. On the other hand, CrossfireTM showed significant oxidation subsequent to the artificial aging, which was also reflected on its wear behavior. In fact, wear rate and oxidation level of aged CrossfireTM were even higher than those of the aged control polyethylene. This observation raises significant concerns on the long-term stability of the gamma sterilized highly crosslinked UHMWPEs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wear of highly crosslinked polyethylene acetabular components

BACKGROUND AND PURPOSE Wear rates of highly crosslinked polyethylene (XLPE) acetabular components have varied considerably between different published studies. This variation is in part due to the different techniques used to measure wear and to the errors inherent in measuring the relatively low amounts of wear in XLPE bearings. We undertook a scoping review of studies that have examined the i...

متن کامل

Wear versus Thickness and Other Features of 5-Mrad Crosslinked UHMWPE Acetabular Liners

BACKGROUND The low wear rates of crosslinked polyethylenes provide the potential to use larger diameters to resist dislocation. However, this requires the use of thinner liners in the acetabular component, with concern that higher contact stresses will increase wear, offsetting the benefits of the crosslinking. QUESTIONS/PURPOSES We asked the following questions: Is the wear of conventional a...

متن کامل

Wear of Crosslinked Uhmwpe in a Hip Joint Simulator

Crosslinking has been extensively introduced to reduce the wear of UHMWPE. In this study the wear rates and wear surfaces of UHMWPE with different levels of crosslinking were compared in a hip joint simulator. The UHMWPE was either non-irradiated, gamma irradiated in air (2.5MRad), or highly crosslinked (7.5 and 10MRad). The intentionally crosslinked materials showed a significantly lower volum...

متن کامل

Comparison of Different Crosslinking Methods for Preparation of Docetaxel-loaded Albumin Nanoparticles

AbstractIn the last step of desolvation method for preparation of albumin nanoparticles, glutaraldehyde (GA) is added to stabilize the newly formed nanoparticles. Due to undesirable effects of GA, the objective of this study was to evaluate alternative methods of crosslinking including ultraviolet (UV) irradiation, adding of glucose and combination of both methods. The nanoparticles were prepar...

متن کامل

Wear comparison between three types of Brelian, Super brelian and Ivocolar artificial teeth ( In - vitro)

Wear comparison between three types of Brelian, Super brelian and Ivocolar artificial teeth ( In - vitro) Dr. S. SH. Shayegh * - Dr. M. Ghorbanian ** * - Assistant Professor of Dental Prosthodontics Dept. - Faculty of Dentistry – Shahed University. ** - Dentist. Background and Aim: Wear is one of the main problems of acrylic teeth that creates a lot of problems for both patient and dentist. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic research : official publication of the Orthopaedic Research Society

دوره 19 6  شماره 

صفحات  -

تاریخ انتشار 2001