Measurement of lung volume and ventilation distribution with an ultrasonic flow meter in healthy infants.

نویسندگان

  • A Schibler
  • G L Hall
  • F Businger
  • B Reinmann
  • J H Wildhaber
  • M Cernelc
  • U Frey
چکیده

Small airway disease in infants is characterised by abnormal lung volume and uneven ventilation distribution. An inert tracer gas washin/washout technique using a pulsed ultrasonic flow meter is presented to measure functional residual capacity (FRC) and ventilation distribution in spontaneously breathing and unsedated infants. With a pulsed ultrasound sent through the main stream of the flow meter, flow, volume and MM of the breathing gas can be calculated. Sulphur hexafluoride was used as a tracer gas. In a mechanical lung model (volume range 53-188 mL) and in 12 healthy infants (aged 38.3+/-9.2 days; mean+/-SD) accuracy and reproducibility of the technique was assessed. Indices of ventilation distribution such as alveolar-based mean dilution number (AMDN) and pulmonary clearance delay (PCD) were calculated. Mean error of volume measurement in the lung model was 0.58% (coefficient of variance (CV) 1.3%). FRC was in the low predicted range for normal infants (18.0+/-2.0 mL x kg(-1)) and highly reproducible (5.5+/-1.7% intra-subject CV). AMDN was 1.63+/-0.15 and PCD was 52.9+/-11.1%. Measurement of functional residual capacity and ventilation distribution using a sulphur hexafluoride washin/washout and an ultrasonic flow meter proved to be highly accurate and reproducible in a lung model and in healthy, spontaneously breathing and unsedated infants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Functional residual capacity measurements in healthy infants: ultrasonic flow meter versus a mass spectrometer.

Accurate, reproducible and portable bedside monitoring of lung volume could potentially facilitate the early recognition of both under and overinflation of the lungs in ventilated and nonventilated subjects. This study asked whether a prototype portable ultrasonic flow meter provided valid and reliable measurements of functional residual capacity (FRCUS) when compared to those obtained using a ...

متن کامل

Lung Volume, Breathing Pattern and Ventilation Inhomogeneity in Preterm and Term Infants

BACKGROUND Morphological changes in preterm infants with bronchopulmonary dysplasia (BPD) have functional consequences on lung volume, ventilation inhomogeneity and respiratory mechanics. Although some studies have shown lower lung volumes and increased ventilation inhomogeneity in BPD infants, conflicting results exist possibly due to differences in sedation and measurement techniques. METHO...

متن کامل

Piezoceramic Element Design and Fabrication for Ultrasonic Transducer of Gas Meter

Ultrasonic transducers play a significant role in generating and receiving the acoustic waves in ultrasonic flowmeters. Depending on the required accuracy, the ultrasonic transducers can be installed either in one pair or more in an ultrasonic flowmeter. The main part of an ultrasonic transducer is its piezoceramic element. In this work, four piezoceramic elements with different diameter to thi...

متن کامل

Normative data for lung function and exhaled nitric oxide in unsedated healthy infants.

Despite association with lung growth and long-term respiratory morbidity, there is a lack of normative lung function data for unsedated infants conforming to latest European Respiratory Society/American Thoracic Society standards. Lung function was measured using an ultrasonic flow meter in 342 unsedated, healthy, term-born infants at a mean ± sd age of 5.1 ± 0.8 weeks during natural sleep acco...

متن کامل

A simple and novel method for acoustic streaming power measurement of ultrasonic horn

Ultrasonic horn with transfer of acoustic wave into an aqueous solution results in unique properties. When, transfer of sound wave into a liquid results in liquid movement in the direction of wave propagation which gradually loses its energy due to the viscous friction. This wave motion induces a flow which is known as acoustic streaming or micro-streaming. In this article, a simple innovative ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 20 4  شماره 

صفحات  -

تاریخ انتشار 2002