Automatic Detection of Quiescent Cardiac Phases using Navigator Echoes with Adjacent Complex Correlation Algorithm
نویسندگان
چکیده
PURPOSE In many cardiac imaging applications, the accurate detection of the systolic and diastolic quiescent periods is critical in obtaining optimal image quality and is usually determined by observing cardiac motion in a CINE acquisition. This complicates the cardiac exam procedure and does not adapt to heart rate variations throughout the exam. In this study, we investigated the feasibility of an automatic detection technique that could detect both cardiac and respiratory motion, and could be adapted to various cardiac sequences.
منابع مشابه
Extraction of the Longitudinal Movement of the Carotid Artery Wall using Consecutive Ultrasonic Images: a Block Matching Algorithm
Introduction: In this study, a computer analysis method based on a block matching algorithm is presented to extract the longitudinal movement of the carotid artery wall using consecutive ultrasonic images. A window (block) is selected as the reference block in the first frame and the most similar block to the reference one is found in the subsequent frames. Material and Methods: The program was...
متن کاملAutocorrection in MR imaging: adaptive motion correction without navigator echoes.
A technique for automatic retrospective correction of motion artifacts on magnetic resonance (MR) images was developed that uses only the raw (complex) data from the MR imager and requires no knowledge of patient motion during the acquisition. The algorithm was tested on coronal images of the rotator cuff in a series of 144 patients, and the improvements in image quality were similar to those a...
متن کاملNovel Motion Correction Technique Using Orbital Navigator Echoes in Interleaved Spiral Imaging
Spiral imaging does not produce apparent flow artifacts. However, it remains sensitive to rapid rigid body motion. In this abstract, a motion correction technique using an orbital navigator “ring” in interleaved spiral imaging is presented. In this technique, a circular k-space trajectory is incorporated into each spiral interleaf. Data inconsistency due to both rotation and translation can be ...
متن کاملAn accurate, robust, and computationally efficient navigator algorithm for measuring diaphragm positions.
PURPOSE The purpose of this study is to develop an improved algorithm for measuring the position of the diaphragm using navigator echoes. METHODS This algorithm was applied to navigator echo data acquired from 14 cardiac patients. For each patient, 160 navigator echo profiles were acquired across the right hemi-diaphragm along the superior-inferior direction. RESULTS The accuracy of the pro...
متن کاملObjective Peak-Detection in Complex Auditory Brainstem Response to /ba/, /da/, /ga/: A Novel Technique
Objectives: The result of auditory brainstem response is used worldwide for detecting hearing impairments or hearing aids. This study aimed to introduce the superiority of mathematical innovation algorithm toward subjective evaluation by an audiologist. The automatic algorithm method is encouraged for detecting the waves of Auditory Brainstem Response (ABR), because it can reduce subjective eva...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008