Comparing Tuberculosis Diagnostic Yield in Smear/Culture and Xpert® MTB/RIF-Based Algorithms Using a Non-Randomised Stepped-Wedge Design.
نویسندگان
چکیده
SETTING Primary health services in Cape Town, South Africa. STUDY AIM To compare tuberculosis (TB) diagnostic yield in an existing smear/culture-based and a newly introduced Xpert® MTB/RIF-based algorithm. METHODS TB diagnostic yield (the proportion of presumptive TB cases with a laboratory diagnosis of TB) was assessed using a non-randomised stepped-wedge design as sites transitioned to the Xpert® based algorithm. We identified the full sequence of sputum tests recorded in the electronic laboratory database for presumptive TB cases from 60 primary health sites during seven one-month time-points, six months apart. Differences in TB yield and temporal trends were estimated using a binomial regression model. RESULTS TB yield was 20.9% (95% CI 19.9% to 22.0%) in the smear/culture-based algorithm compared to 17.9% (95%CI 16.4% to 19.5%) in the Xpert® based algorithm. There was a decline in TB yield over time with a mean risk difference of -0.9% (95% CI -1.2% to -0.6%) (p<0.001) per time-point. When estimates were adjusted for the temporal trend, TB yield was 19.1% (95% CI 17.6% to 20.5%) in the smear/culture-based algorithm compared to 19.3% (95% CI 17.7% to 20.9%) in the Xpert® based algorithm with a risk difference of 0.3% (95% CI -1.8% to 2.3%) (p = 0.796). Culture tests were undertaken for 35.5% of smear-negative compared to 17.9% of Xpert® negative low MDR-TB risk cases and for 82.6% of smear-negative compared to 40.5% of Xpert® negative high MDR-TB risk cases in respective algorithms. CONCLUSION Introduction of an Xpert® based algorithm did not produce the expected increase in TB diagnostic yield. Studies are required to assess whether improving adherence to the Xpert® negative algorithm for HIV-infected individuals will increase yield. In light of the high cost of Xpert®, a review of its role as a screening test for all presumptive TB cases may be warranted.
منابع مشابه
Evaluation of GeneXpert MTB/RIF for detection of Mycobacterium tuberculosis complex and rpo B gene in respiratory and non-respiratory clinical specimens at a tertiary care teaching hospital in Saudi Arabia
OBJECTIVES To assess the performance of Xpert MTB/RIF, an automated molecular test for Mycobacterium tuberculosis (MTB) and resistance to rifampin (RIF), against smear microscopy and culture method for diagnosis of MTB infection. Methods: This is a retrospective analysis of 103 respiratory and 137 non-respiratory patient specimens suspected of tuberculosis at King Khalid University Hospital, Ri...
متن کاملPerformance of Xpert® MTB/RIF among tuberculosis outpatients in Lilongwe, Malawi
BACKGROUND Xpert® MTB/RIF is a molecular test for the detection of Mycobacterium tuberculosis and rifampicin resistance. It is considered to be a great advance over smear microscopy and culture. However, there is very little information regarding the performance characteristics of Xpert MTB/RIF in Malawi. OBJECTIVE We aimed to evaluate the performance of Xpert MTB/RIF in a Malawian setting. ...
متن کاملIntensified Tuberculosis Case-Finding in HIV-Positive Adults Managed at Ethiopian Health Centers: Diagnostic Yield of Xpert MTB/RIF Compared with Smear Microscopy and Liquid Culture
BACKGROUND Detection of active tuberculosis (TB) before antiretroviral therapy (ART) initiation is important, but optimal diagnostic methods for use in resource-limited settings are lacking. We assessed the prevalence of TB, evaluated the diagnostic yield of Xpert MTB/RIF in comparison with smear microscopy and culture, and the impact of Xpert results on clinical management in HIV-positive adul...
متن کاملCorrection: Impact of Replacing Smear Microscopy with Xpert MTB/RIF for Diagnosing Tuberculosis in Brazil: A Stepped-Wedge Cluster-Randomized Trial
BACKGROUND Abundant evidence on Xpert MTB/RIF accuracy for diagnosing tuberculosis (TB) and rifampicin resistance has been produced, yet there are few data on the population benefit of its programmatic use. We assessed whether the implementation of Xpert MTB/RIF in routine conditions would (1) increase the notification rate of laboratory-confirmed pulmonary TB to the national notification syste...
متن کاملDiagnosis of smear-negative tuberculosis is greatly improved by Xpert MTB/RIF
BACKGROUND Diagnosis of pulmonary (PTB) and extra-pulmonary tuberculosis (EPTB) in smear-negative patients can be difficult. We assessed retrospectively the performance of Xpert MTB/RIF system (Xpert, Cepheid) in diagnosing smear-negative tuberculosis (TB), which represents the most common form of TB in a low incidence setting. METHODS Performance of Xpert was compared to acid-fast microscopi...