Percutaneous device closure of atrial septal defect with totally transthoracic echocardiography guide, without x-ray machine
نویسندگان
چکیده
The present study investigated the feasibility of totally transthoracic echocardiography-guided percutaneous device occlusion of atrial septal defects (ASDs) without using x-ray equipment.Between September and December 2014, we performed totally transthoracic echocardiography-guided percutaneous device occlusion for 20 patients with secundum ASD without using x-ray equipment. We carried out percutaneous femoral vein puncture, used a specialized delivery sheath during operation, and closed the ASD by releasing an occluder.All 20 patients experienced successful occlusion and smoothly went through the perioperative period. The average procedure time ranged from 30 to 40 minutes (32.4 ± 3.5 minutes), and the size of the implanted occluder ranged from 20 to 38 mm (25.4 ± 5.8 mm). No occluder displacements, residual fistula, or thrombus-related complications after the procedure. There was no clinical death, no arrhythmia, no hemolysis, no infection, or embolism during patients' hospitalization and the follow-up period.Totally transthoracic echocardiography-guided percutaneous device occlusion of ASDs without the use of x-ray equipment may be safe and feasible.
منابع مشابه
Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty
Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...
متن کاملUrgent Surgical Intervention for Embolized Cardiac Occluder Devices: A Case Series
Introduction: In this study, we sought to illustrate our experience in urgent surgical management for embolized cardiac septal occlude devices resulting from trans-catheter closure of atrial septal defect and ventricular septal defect. Mathrials and Methods: We retrospectively reviewed four patients aged 2–10 years who underwent urgent surgery due to cardiac septal occluder embolization between...
متن کاملTranscatheter closure of atrial septal defects with transthoracic echocardiography.
OBJECTIVES The aim of this study is to evaluate our clinical experience using an Amplatzer septal occluder for catheter closure of a secundum atrial septal defect under transthoracic echocardiography guidance without general anaesthesia. METHODS Patients eligible for transcatheter atrial septal defect closure were selected using transthoracic echocardiography. The largest defect diameter meas...
متن کاملEvaluation of Clinical Course in Children and Adolescents with Atrial Septal Defects
Background Atrial septal defects (ASDs) are the most common third congenital heart defects. This study aimed to evaluate the clinical course of ASDs and the relationship between its complications, location closure and size. Materials and Methods: This cross-sectional study was conducted...
متن کاملFeasibility and Safety of Transthoracic Echocardiography-Guided Transcatheter Closure of Atrial Septal Defects with Deficient Superior-Anterior Rims
Although previous studies showed that transthoracic echocardiography (TTE) can be used to guide transcatheter closure of atrial septal defect (ASD), whether TTE can be used to guide transcatheter closure of secundum ASD with a deficient superior-anterior rim is unknown and this critical issue was addressed in the present study. A total of 280 patients with secundum ASD who underwent transcathet...
متن کامل